Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330101-00-10-10-02-00
3300 XL 8mm Probe Bently Nevada 330101-00-10-10-02-00
Manufacturer: Bently Nevada
Product No.: 330101-00-10-10-02-00
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 330101-00-10-10-02-00 3300 XL 8 mm Proximity Probe
Bently Nevada 330101-00-10-10-02-00 is a 3300 XL series 8 mm proximity probe with 3/8-24 UNF thread, 1.0 inch case length, 1.0 meter cable, and ClickLoc connector. Features PPS tip, patented TipLoc and CableLoc designs, and 330N pull strength.
Model Configuration
| Parameter | Value |
|---|---|
| Full Model | 330101-00-10-10-02-00 |
| Probe Type | 3300 XL 8 mm, 3/8-24 UNF thread, no armor |
| Unthreaded Length | 00 = 0.0 in |
| Overall Case Length | 10 = 1.0 in |
| Total Length | 10 = 1.0 m (3.3 ft) |
| Connector & Cable Type | 02 = Miniature coaxial ClickLoc, standard cable |
| Agency Approval | 00 = Not required |
DC Resistance & Capacitance
| Parameter | Value |
|---|---|
| Probe DC Resistance (1.0m) | 7.59 ± 0.50 ohms |
| Extension Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
Physical Specifications
| Component | Material / Value |
|---|---|
| Tip Material | PPS (Polyphenylene sulfide) |
| Case Material | AISI 303 or 304 Stainless Steel |
| Cable Pull Strength | 330 N (75 lbf) - CableLoc design |
| Weight | 323 g/m (11.4 oz/m) |
Performance Specifications
| Parameter | Value |
|---|---|
| Linear Range | 2 mm (80 mils) from 0.25 to 2.3 mm |
| Recommended Gap (Radial Vibration) | -9 Vdc (approx 1.27 mm / 50 mils) |
| ISF (1/5m System) | 7.87 V/mm (200 mV/mil) ±5% |
| ISF (9m System) | 7.87 V/mm (200 mV/mil) ±6.5% |
| DSL (1/5m System) | ±0.025 mm (±1 mil) @ 0°C to +45°C |
Field Wiring
- Wire size: 0.2 to 1.5 mm² (16 to 24 AWG)
- Recommended: 3 conductor shielded triad cable with tinned wiring
- Maximum length: 305 m (1,000 ft) between Proximitor Sensor and monitor
Temperature Range
| Condition | Range |
|---|---|
| Standard Probe Operating | -52°C to +177°C (-62°F to +350°F) |
| ETR Probe Tip | -52°C to +218°C (-62°F to +425°F) |
| ETR Cable & Connector | -51°C to +260°C (-60°F to +500°F) |
Design Features
- Patented TipLoc molding for robust tip-to-body bond
- Patented CableLoc design with 330 N (75 lbf) pull strength
- Optional FluidLoc cable prevents oil leakage through cable interior
- Thicker PPS encapsulation for rugged durability
- Viton® O-ring pressure seal
FAQs
Q1: What is the recommended gap setting for radial vibration?
A1: -9 Vdc, approximately 1.27 mm (50 mils) from target.
Q2: What is the linear range of this probe?
A2: 2 mm (80 mils) from 0.25 to 2.3 mm (10 to 90 mils).
Q3: What is the cable pull strength?
A3: 330 N (75 lbf) with CableLoc design.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
-
How Do Bently Nevada Transmitters Improve Bearing Health Monitoring?
This technical article examines the role of Bently Nevada vibration transmitters in industrial automation for ea...
-
What Are the Real ROI Gains of Upgrading Legacy Turbine Monitoring?
Operating legacy turbine supervisory instrumentation (TSI) beyond 12 years exposes power stations to false trips, pro...
-
How Does 3500/22M Improve Mixed-Vendor Safety Integration?
This article examines the measurable performance gap between Bently Nevada's legacy 3500/22 and the upgraded 3500/22M...
-
Fixed Gas Detector or Transmitter: Which Fits Your Plant?
This article examines the practical differences between fixed gas detectors and gas detection transmitters in industr...