Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:22B-E3P0C104
22B-E3P0C104 PowerFlex 40 Drive RS-485 16kHz PWM Allen-Bradley
Manufacturer: Allen-Bradley
Product No.: 22B-E3P0C104
Product Type: AC Drive
Product Origin: USA
Payment:T/T, Western Union
Weight: 6500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 22B-E3P0C104 PowerFlex 40 AC Drive
Product Overview
The Allen-Bradley 22B-E3P0C104 PowerFlex 40 Series AC drive delivers 2 HP (1.5 kW) output with 3.0 A current capacity. Operating on 600 VAC 3-phase input, this B Frame drive features sensorless vector and V/Hz control with Autotune. The IP66/NEMA 4X enclosure provides dust-tight and water-resistant protection. Weight is 6.5 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 22B-E3P0C104 |
| Series | PowerFlex 40 |
| Drive Type | Adjustable Frequency AC Drive |
| Input Voltage | 600 VAC, 3-Phase, 50/60 Hz |
| Output Power | 2 HP (1.5 kW) |
| Output Current | 3.0 A |
| Enclosure Type | IP66 / NEMA 4X (Dust-tight, Water-resistant) |
| Frame Size | B Frame |
| Control Mode | Sensorless Vector, V/Hz, Autotune |
| Operating Temperature | -10 °C to +40 °C (Zero Stacking to 50 °C) |
| Display | 4-digit LED + 10 status indicators + Keypad |
| Communication | Built-in RS-485 + Optional (DeviceNet, ControlNet, EtherNet/IP, PROFIBUS DP, LonWorks, DSI Wireless) |
| Integrated Functions | PID, Timer, Counter, Basic Logic, StepLogic |
| Braking | Integral brake transistor |
| PWM Frequency | Adjustable up to 16 kHz |
| Protection | Removable MOV, Overload, Relay Pre-Charge Circuit |
| Mounting | DIN Rail or Panel Mount |
| Weight | 6.5 kg |
Key Features
- 600 VAC 3-phase input for high-voltage applications
- Sensorless vector and V/Hz control with Autotune
- IP66 / NEMA 4X dust-tight and water-resistant enclosure
- Built-in RS-485 with optional fieldbus modules
- Integrated PID, Timer, Counter, Logic, and StepLogic functions
- Integral brake transistor for dynamic braking
- Adjustable PWM frequency up to 16 kHz
- Removable MOV, overload, and relay pre-charge protection
- DIN rail or panel mounting flexibility
Installation Notes
Mount the drive on DIN rail or panel using the B Frame mounting provisions. Ensure adequate clearance for airflow. The IP66/NEMA 4X enclosure allows installation in washdown or dusty environments. Set motor parameters using the integral keypad or RS-485 communication.
FAQs
Q1: What is the maximum ambient temperature for zero stacking?
A1: Zero stacking is supported up to 50 °C. For operation above 40 °C, derating may apply.
Q2: Can this drive be used with single-phase input?
A2: No. The 22B-E3P0C104 requires 3-phase 600 VAC input for proper operation.
Q3: What communication options are available?
A3: Built-in RS-485 is standard. Optional modules support DeviceNet, ControlNet, EtherNet/IP, PROFIBUS DP, LonWorks, and DSI Wireless.
Ƙarin ƙayyadaddun bayanai
- Baƙi
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Staged Hardware Upgrades Eliminate Unplanned Downtime?
This technical article examines the hidden risks of ageing Allen‑Bradley PLC and DCS hardware in continuous process e...
-
Is Protocol Conversion Key to Unified Factory Automation?
Mixed-vendor PLC and DCS environments create significant operational inefficiencies and unplanned downtime in modern ...
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...