Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1785-L46C15
1785-L46C15 Allen-Bradley PLC-5/46C ControlNet Processor
Manufacturer: Allen-Bradley
Product No.: 1785-L46C15
Product Type: Processor Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1420g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
1785-L46C15 Allen-Bradley PLC-5/46C ControlNet Processor – Protected Memory
The Allen-Bradley 1785-L46C15 is a ControlNet PLC-5/46C processor with protected memory. Provides 48 Kilowords of user memory with battery-backed static RAM. Weight is approximately 1.42 kg (3 lbs).
Product Information
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1785-L46C15 |
| Module Type | ControlNet PLC-5 Processor with Protected Memory |
| Processor | PLC-5/46C |
| Max User Memory | 48 Kilowords |
| Protected Memory | Yes |
| Weight | Approx. 1.42 kg (3 lbs) |
I/O and Memory Specifications
| Battery-Backed Static RAM | Yes |
| EEPROM Backup Option | Yes (1785-ME16, -ME32, -ME64, -M100) |
| Max Forcible I/O | 2048 (Any Mix) or 2048 In + 2048 Out |
| Max Nonforcible I/O | 48000 |
| Max I/O Chassis Total | 125 |
| Max Universal Remote Chassis | 60 |
Communication and Power Specifications
| ControlNet I/O Scan Time | 0.5 ms Average per Rack |
| Remote I/O Scan (57.6 kbit/s) | 10 ms per Rack |
| Remote I/O Scan (115.2 kbit/s) | 7 ms per Rack |
| Remote I/O Scan (230.4 kbit/s) | 3 ms per Rack |
| Backplane Current | 3.0 A at 5V DC |
| Max Thermal Dissipation | 59 BTU/hour |
| Serial Ports | 1 x RS-232-C/422-A/423-A |
| Coprocessor Port | Yes |
Environmental Specifications
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative Humidity | 5% to 95% Non-Condensing |
| Operational Shock | 30G |
| Vibration | 1G at 10-500 Hz |
Features
- ControlNet PLC-5/46C processor with protected memory
- 48 Kilowords user memory with battery-backed static RAM
- Supports 1785-CHBM ControlNet Hot Backup Cartridge
- Compatible with 1771, 1794, 1746, and 1791 I/O modules
- ControlNet redundant port with 5 Mbit/s speed
- Supports ½ slot, single slot, and double slot hardware addressing
- Open-style enclosure
- Lightweight design at approximately 1.42 kg (3 lbs)
FAQs
Q1: How much user memory does the 1785-L46C15 provide?
A1: 48 Kilowords with battery-backed static RAM and EEPROM program backup option.
Q2: What is the maximum I/O capacity?
A2: 2048 forcible points (any mix) or 48000 nonforcible points.
Q3: What is the weight and power consumption?
A3: Approximately 1.42 kg (3 lbs) with 3.0 A backplane current at 5V DC and 59 BTU/hour thermal dissipation.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
