Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1762-L40AWA
1762-L40AWA Allen-Bradley Controller | 120VAC Input 1440VA Load
Manufacturer: Allen-Bradley
Product No.: 1762-L40AWA
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1090g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1762-L40AWA MicroLogix 1200 Controller
Product Overview
The Allen-Bradley 1762-L40AWA is a 40-point programmable controller from the MicroLogix 1200 series. It features 24 inputs rated at 120 VAC and 16 relay outputs with a 24-125 VDC / 120-240 VAC contact rating. Powered by 120-240 VAC external supply, the controller includes 2 trim potentiometers for local control and one 8-pin mini-DIN communication port. Weight is 2.4 lbs (1.09 kg).
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1762-L40AWA |
| Series | MicroLogix 1200 |
| Module Type | Programmable Controller |
| Input Power | 120-240 VAC, 47-63 Hz |
| Inputs | 24 (120 VAC) |
| Outputs | 16 Relay |
| Relay Contact Rating | 24-125 VDC; 120-240 VAC |
| Mechanical Cycles | 20,000,000 |
| Load Current | 10 A minimum |
| Max Load Capacity | 1,440 VA |
| Current per Group Common | 8 A |
| On-State Voltage (Ch 0-3) | 14-24 VDC |
| On-State Voltage (Ch 4+) | 10-24 VDC |
| Off-State Voltage | 0-5 VDC |
| Min Off-State Leakage | 1.5 mA |
| Communication Port | 1 x 8-Pin mini-DIN |
| Supported Protocols | DF1, DH-485, ASCII, MODBUS |
| Power Supply Usage | 82 VA |
| Inrush Current (120V AC) | 25 A for 8 ms |
| Inrush Current (240V AC) | 40 A for 4 ms |
| Dimensions (H x W x D) | 90 x 160 x 87 mm (104 mm with DIN latch open) |
| Operating Temperature | 0 to 55 °C |
| Weight | 2.4 lbs (1.09 kg) |
| UPC | 10612598207227 |
Key Features
- 40-point controller with 24 inputs and 16 relay outputs
- 120 VAC input rating with 120-240 VAC power supply
- Relay contact rating 24-125 VDC / 120-240 VAC
- 20,000,000 mechanical cycle relay rating
- Max load capacity 1,440 VA with 8 A per group common
- Two trim potentiometers for local control
- One 8-pin mini-DIN communication port
- Supports DF1, DH-485, ASCII, and MODBUS protocols
- Operating frequency 47-63 Hz
- Compact design with 2-inch clearance requirement
Installation Notes
Supply external 100-240 VAC power at 47-63 Hz. Ensure output load does not exceed 8 A per group common to prevent module damage. The inrush current is 25 A for 8 ms at 120 VAC and 40 A for 4 ms at 240 VAC. Use the 8-pin mini-DIN port for program download/upload, HMI, and SCADA interfacing. Trim potentiometers located on the front panel can be adjusted with a precision screwdriver for local control.
FAQs
Q1: How many I/O points does the 1762-L40AWA have?
A1: 24 inputs (120 VAC) and 16 relay outputs, totaling 40 I/O channels.
Q2: What is the maximum load capacity?
A2: Up to 1,440 VA, with a maximum of 8 A per group common.
Q3: What communication protocols are supported?
A3: DF1, DH-485, ASCII, and MODBUS Master/Slave protocol.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...
-
How Can You Migrate ABB PLCs Without Stopping Production?
Aging ABB PLC platforms create rising reliability and spare-part risks for process plants. This article explains wher...
-
How Does Honeywell DCS Modernization Cut Refinery Downtime?
Honeywell DCS modernization helps refineries replace aging control hardware without full shutdowns. It tightens proce...
-
Why Do Hybrid DCS-PLC Systems Cause False Trips?
This article explains how to align Emerson DCS anti-surge control with ABB PLC compressor protection in hybrid ind...
-
How Can Brownfield Upgrades Modernize GE Fanuc DCS Visualization?
Aging GE Fanuc DCS visualization stacks create spare part delays, alarm chaos and unplanned downtime. This article ex...
