Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1746-P3
1746-P3 | Allen-Bradley SLC 500 DC Power Supply 24V 3.6A
Manufacturer: Allen-Bradley
Product No.: 1746-P3
Product Type: Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1746-P3 SLC 500 DC Power Supply
Product Overview
The Allen-Bradley 1746-P3 is a DC power supply module for the SLC 500 controller platform. It operates at 19.2-28.8 VDC input and provides backplane power of 3.6 A at 5Vdc and 0.87 A at 24Vdc. Mounted at the left-most position of the chassis without occupying a slot, this module is certified for Class 1 Division 2 hazardous locations. Weight is 1.1 kg (2.5 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1746-P3 |
| Series | SLC 500 |
| Module Type | Power Supply |
| Input Voltage Range | 19.2-28.8 VDC |
| Nominal Input Voltage | 24 VDC |
| Input Power | 61 W |
| Typical Line Power | 90 VA |
| Inrush Current | 20 A |
| Current Capacity (5V) | 3.6 A |
| Current Capacity (24V) | 0.87 A |
| Backplane Current (5V) | 3.6 A |
| Backplane Current (24V) | 0.87 A |
| Hold-up Time (Full Load) | 5 ms |
| Hold-up Time (No Load) | 1000 ms |
| Isolation Voltage | 600V AC RMS for 1s (Version B+) |
| Fuse Protection | 1746-F3 or equivalent |
| Operating Temperature | 0 to 60 °C (32 to 140 °F) |
| Deration | 5% above 55 °C |
| Location | Left-most, 1746 Chassis |
| Dimensions (W x D x H) | 79.2 x 144.8 x 139.7 mm |
| Weight | 1.1 kg (2.5 lbs) |
Key Features
- Provides backplane power to SLC 500 chassis modules
- 19.2-28.8 VDC input with 24 VDC nominal
- 3.6 A at 5Vdc and 0.87 A at 24Vdc current capacity
- Mounted at left-most position, no chassis slot required
- 5 ms hold-up time at full load, 1000 ms at no load
- UL and C-UL Listed for Class 1 Div 2 hazardous locations
- 600V AC RMS isolation (Version B and later)
- Replaceable fuse (1746-F3 or equivalent)
- Designed for altitudes up to 2000 meters without derating
- Pollution Degree 2 and Category II rated
Installation Notes
Mount the power supply at the left-most position of the 1746 chassis. Use 1746-F3 fuse or equivalent (BUSSMAN AGC 5 or Nagasawa ULCS-61ML-5). Only 1/8 inch flat head and 1/4 inch Phillips head screwdrivers are required for installation. Observe ESD precautions: keep in static-shield packaging when not in use, avoid touching connector pins or circuit components.
FAQs
Q1: What is the input voltage range for the 1746-P3?
A1: 19.2-28.8 VDC with 24 VDC nominal.
Q2: What is the hold-up time at full load?
A2: 5 ms at full load, 1000 ms at no load.
Q3: Is this module certified for hazardous locations?
A3: Yes. UL and C-UL Listed for Class 1, Division 2, Groups A, B, C, D Hazardous Locations.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How to Modernize Discrete Manufacturing Without Stopping Production?
This article presents a strategic incremental approach to modernizing discrete manufacturing workshops using Allen‑Br...
-
How Can Custom ABB Control Cut Downtime by 40%?
This article examines how custom-tailored ABB control engineering addresses hidden risks in legacy process facilities...
-
Can Unified DCS Architecture Cut Plant Downtime by 35%?
This article examines full-plant automation architecture through measurable outcomes from ABB DCS real-world deployme...
-
How Intelligent Scheduling Cuts Downtime & Boosts OEE 12%?
This article examines how intelligent production scheduling transforms industrial automation by replacing static spre...
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...