Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:1734-APB
1734-APB Allen-Bradley POINT I/O PROFIBUS DP Adapter
Manufacturer: Allen-Bradley
Product No.: 1734-APB
Product Type: Adapter Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Allen-Bradley 1734-APB POINT I/O PROFIBUS DP Adapter
The Allen-Bradley 1734-APB is a compact POINT I/O PROFIBUS DP network adapter module engineered to bridge field-level POINT I/O modules with a PROFIBUS DP network. Weighing approximately 0.55 lbs (0.25 kg), it is installed on the far left side of a 1734 assembly, acting as a master on the backplane PointBus—supporting up to 63 I/O expansion modules—and operating as a slave device on the overarching PROFIBUS network. Operating on a nominal 24V DC input (10–28.8V DC range), the module converts field power into 5V DC logic power, delivering up to 1000 mA of PointBus backplane current. Built with reverse polarity protection and an IP20-rated form factor, it provides reliable communication, 8W max power consumption, and 10 ms power-loss hold-up time for demanding industrial automation environments.
Technical Specifications
| Manufacturer & Series | Allen-Bradley POINT I/O |
| Catalog / Part Number | 1734-APB |
| Module Type | PROFIBUS DP Network Adapter Module |
| Input Voltage Range | 24V DC Nominal (10.0 to 28.8V DC) |
| Inrush Current | 6 A Maximum for 10 milliseconds |
| POINTBus Output Current | 1000 mA (1 A) @ 5V DC ±5% |
| Field Side Power Current | 400 mA Maximum @ 24V DC |
| Power Consumption & Dissipation | 8.0 W Consumption | 2.8 W Dissipation (@ 28.8V DC) |
| Overvoltage / Input Protection | Reverse Polarity Protection |
| Expansion Capacity | Up to 63 POINT I/O Modules Maximum |
| Approximate Weight | 0.55 lbs (0.25 kg) |
| Power Supply Requirements | SELV, PELV, or Class 2 Power Supply (CE Compliant) |
Quick Installation Guide
- Mount the 1734-APB adapter at the extreme left position of the DIN rail system before adding POINT I/O modules.
- Connect a certified 24V DC SELV/PELV power source to the adapter terminals, maintaining correct polarity.
- Plug in the 9-pin D-shell PROFIBUS DP connector and configure node addressing according to network layout.
Technical FAQs
Q1: How many I/O modules can 1734-APB supply?
A1: It supports up to 63 total modules, providing up to 1000 mA of 5V backplane logic current.
Q2: What is the operating input voltage range?
A2: Nominal 24V DC with an allowable range of 10.0 to 28.8V DC.
Q3: Does the module include input surge protection?
A3: Yes, it features integrated reverse polarity protection for overvoltage safety.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can ABB’s Signal Linkage Cut Downtime 60%?
This article examines how ABB’s multi-layer industrial communication architecture resolves cross-equipment signal mis...
-
Is Your Gas Detection Transmitter Costing You Millions?
Fixed calibration schedules waste millions and hide critical risks. This article presents a data-driven, risk-tiered ...
-
Is Your PLC and DCS Logic Hiding Energy Savings?
This article presents a three-layer framework for industrial energy optimization using ABB automation technology. It ...
-
How Can Real-Time Data Governance Prevent Unplanned Downtime?
Uncalibrated sensors and inconsistent tag naming are causing a trillion-dollar "data debt" in process manufacturing. ...
-
Can Programmable Interlock Eliminate 31% of Assembly Downtime?
This engineering guide examines programmable interlock logic for assembly lines using Allen‑Bradley control platforms...
-
How ABB's Risk Platform Cuts Industrial Plant Downtime?
ABB's intelligent risk identification platform addresses unresolved safety gaps in conventional control-system operat...
