Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:8200-1302
Woodward 8200-1302 Flex505 LVDC Controller 8.4 Display
Manufacturer: Woodward
Product No.: 8200-1302
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 1850g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
8200-1302 Woodward Flex505 Marine/ATEX LVDC Controller
8200-1302 is a Woodward Flex505 controller with Marine and ATEX compliance. Features 8.4" graphical display (800x600), LVDC power 18-32 Vdc, isolated communications, and extensive I/O. Operating range -30°C to +70°C.
Core Technical Advantages
- Marine/ATEX Certified: Compliant for marine and hazardous area installations.
- 8.4" Graphical Display: 800x600 resolution with keypad for local operation.
- Flexible Power Options: LVDC version 18-32 Vdc, isolated.
- 4 Ethernet Ports: Isolated 10/100 communication ports for network redundancy.
- 4 CAN Ports: 1 Mbit isolated ports support RTCnet and LINKnet HT distributed I/O.
- Wide I/O Count: 2 speed sensors, 8 analog inputs, 6 analog outputs, 20 discrete inputs, 8 relay outputs.
- GAP Configurable: Update rates from 5 ms to 160 ms.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 8200-1302 |
| Description | Flex505 Marine/ATEX LVDC Controller |
| Supply Voltage | 18 - 32 Vdc, isolated |
| Display | 8.4" LCD, 800x600, with keypad |
| Ethernet Ports | 4 x 10/100, isolated |
| CAN Ports | 4 x 1 Mbit, isolated |
| Serial Ports | 1x RS-232/RS-485, 1x RS-232 Service |
| Update Rates | 5 ms to 160 ms (GAP configurable) |
| Speed Sensor Inputs | 2 (MPU/Prox with Prox Power) |
| Analog Inputs | 8 x 4-20mA (with Loop Power) |
| Analog Outputs | 6 x 4-20mA |
| Actuator Outputs | 2 (configurable 4-20mA / 20-200mA) |
| Discrete Inputs | 20 (with Contact Power) |
| Relay Outputs | 8 x Form-C |
| Operating Temp | -30°C to +70°C |
| Certification | Marine / ATEX |
| Brand | Woodward |
Installation & Maintenance Guide
- Mounting: Same installation/mounting as current 505 product line. Front panel mounting.
- Power Supply: Connect 18-32 Vdc isolated input. Ensure adequate capacity for full I/O load.
- Communications: Use shielded cables for Ethernet, CAN, and serial ports. Maintain proper isolation.
- I/O Configuration: GAP configurable update rates from 5 ms to 160 ms per application requirements.
- Environment: Operating range -30°C to +70°C with display. Marine and ATEX compliant installations.
Engineering Advantages & Compatibility
Significant upgrade to the existing 505 product line with enhanced CPU, graphical display, and I/O. Supports expanded I/O options using Woodward CAN distributed I/O nodes (RTCnet and LINKnet HT). Ideal for marine, offshore, and hazardous area turbine/genset control applications. 4 Ethernet ports enable network redundancy. 4 CAN ports support distributed I/O expansion.
Technical FAQs
Q1: What is the difference between 8200-1302 and standard Flex505?
A1: 8200-1302 is the LVDC version (18-32 Vdc) with Marine and ATEX compliance for hazardous area and marine installations.
Q2: What distributed I/O options are supported?
A2: Supports Woodward RTCnet and LINKnet HT CAN distributed I/O nodes for expanded I/O capacity.
Q3: What update rates are configurable?
A3: GAP configurable update rates from 5 ms to 160 ms, allowing optimization for different application speeds.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can Staged Hardware Upgrades Eliminate Unplanned Downtime?
This technical article examines the hidden risks of ageing Allen‑Bradley PLC and DCS hardware in continuous process e...
-
Is Protocol Conversion Key to Unified Factory Automation?
Mixed-vendor PLC and DCS environments create significant operational inefficiencies and unplanned downtime in modern ...
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-