Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1746-IO8
SLC 500 Digital Combination Module 1746-IO8 | Allen-Bradley
Manufacturer: Allen-Bradley
Product No.: 1746-IO8
Product Type: Combination Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 280g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 1746-IO8 SLC 500 AC Digital Combination Module
The Allen-Bradley 1746-IO8 is a versatile combination digital I/O module engineered for the SLC 500 modular control architecture. Weighing approximately 0.28 kg (0.62 lbs), this compact card features 4 digital 120V AC inputs and 4 Normally Open (N.O.) relay contact outputs in a single common group, providing an efficient solution for small-to-medium industrial control tasks.
Key System & Hazardous Area Features
Approved for Class 1, Division 2 (Groups A, B, C, D) hazardous environments, the 1746-IO8 operates with an AC input voltage range of 85 to 132V AC. Relay outputs support switching up to 1.5A at 120V AC and 1.2A at 24V DC. With low thermal dissipation (3W total aggregate), NEMA ICS 2-230 noise immunity, and CE/CSA/C-UL compliance, it delivers high operational stability under heavy shock (30G) and vibration conditions.
Technical Specifications
| Manufacturer & Series | Rockwell Automation | Allen-Bradley SLC 500 |
| Part / Catalog Number | 1746-IO8 |
| Module Configuration | Combination Module (4 AC Inputs / 4 Relay Outputs) |
| Input Operating Voltage | 85…132V AC @ 47…63 Hz |
| Output Voltage & Current | 5…265V AC / 5…125V DC | 1.5A @ 120VAC / 1.2A @ 24VDC |
| Signal Delay & Heat Dissipation | 35…45 ms Delay | 3 Watts Aggregate Heat Dissipation |
| Backplane Power Consumption | 30 mA (0.03A) @ 5V DC | 25 mA (0.025A) @ 24V DC |
| Hazardous Location Ratings | Class 1, Division 2, Groups A, B, C, D Rated |
| Operating Temperature & Weight | 0 °C to +60 °C (32 °F to +140 °F) | Approx. 0.28 kg |
Installation & Handling Guidelines
- Chassis Slot Installation: Mount into any available non-CPU slot (slots 1 through 30) within an SLC 500 1746 I/O chassis. Slot 0 is reserved strictly for the CPU controller.
- Hazardous Location Compliance: When operating in Class 1, Div 2 locations, ensure all field wiring connections are secured and power is disconnected prior to insertion or removal.
- Wiring Layout & Cable Routing: Route input and output field power cabling separately from communication and sensor signal lines to prevent induced electrical noise.
Frequently Asked Questions
Q1: How many inputs and outputs are available on the Allen-Bradley 1746-IO8 module?
A1: The module provides 4 digital 120V AC inputs and 4 Normally Open (N.O.) relay contact outputs.
Q2: Is the 1746-IO8 module suitable for hazardous locations?
A2: Yes, it is rated for installation in Class 1, Division 2, Groups A, B, C, and D hazardous locations.
Q3: What are the backplane power draw specifications for this module?
A3: It draws 0.03A (30 mA) from the 5V DC backplane and 0.025A (25 mA) from the 24V DC backplane.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...
