Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:6ES7441-1AA03-0AE0
Siemens | 6ES7441-1AA03-0AE0 Communication Module Brand New
Manufacturer: Siemens
Product No.: 6ES7441-1AA03-0AE0
Product Type: Communication Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 720g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
SIEMENS 6ES7441-1AA03-0AE0 SIMATIC S7-400 CP 441-1 Communication Module
The SIEMENS 6ES7441-1AA03-0AE0, also cataloged as the CP 441-1 Communication Module, operates as a single-channel point-to-point interface with variable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 connections within SIMATIC S7-400 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7441-1AA03-0AE0 |
| Brand | Siemens |
| Product Type | CP 441-1 Communication Module |
| Series | SIMATIC S7-400 |
| Weight | 720 g (approx.), interface module 100 g |
| Dimensions (W x H x D) | 25 mm x 290 mm x 210 mm |
| Rated Supply Voltage | 5 VDC and 24 VDC |
| Current from Backplane Bus | 700 mA max at 5 VDC (without interface module) |
| Interface Modules | 20 mA (TTY), RS 422/485 (X.27), RS 232C (V.24) |
| Interface Module Consumption | 300 mA max at 5 V; 45 mA max at 24 V (TTY) |
| Number of Interfaces | 1, variable |
| Shielded Cable Length | 1000 m (TTY), 10 m (RS 232), 1200 m (RS 422/485) |
| Transmission Rate | 38.4 kbit/s max overall; 19.2 kbit/s max on TTY |
| Integrated Protocols | 3964 (R), ASCII, Printer |
| Connections | 8 overall |
| Configuration Software | STEP 7 with own parameter assignment forms |
| Memory per Interface | 1 to 5 kbyte parameters; 0 to 55 kbyte message texts |
Variable Interface Physics and Protocol Handling
Unit weight is approximately 720 g with an interface module at approximately 100 g, dimensions of 25 mm width, 290 mm height, and 210 mm depth. The CP 441-1 accepts interchangeable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 (X.27) physics. Shielded cable lengths are limited to 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485. Transmission rate reaches 38.4 kbit/s on RS 422/485 and RS 232, and 19.2 kbit/s on TTY across 3964 (R), ASCII, and printer drivers. Supported printers include HP-Deskjet, HP-Laserjet, IBM-Proprinter, and user-defined models. The module supports 8 connections overall with S7 extended communication. Backplane bus current draw is 700 mA maximum at 5 VDC without an interface module; interface modules draw up to 300 mA at 5 V and 45 mA at 24 V. Parameter memory requirements on the S7-CPU memory card are 1 to 5 kbyte for parameters and 0 to 55 kbyte for message texts. Configuration uses STEP 7 with dedicated parameter assignment forms. A configuration package is included on CD.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7441-1AA03-0AE0?
A: Approximately 720 g, with dimensions of 25 mm width, 290 mm height, and 210 mm depth. The interface module weighs approximately 100 g.
Q: What interface physics does the CP 441-1 support?
A: Interchangeable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 (X.27).
Q: What is the maximum cable length for each interface type?
A: 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485, all with shielded cable.
Field Installation Guidelines
Insert the module into the S7-400 rack and secure the mounting screws. Install the required interface module before energizing. Verify 5 VDC and 24 VDC supply availability. Route shielded cable within the limits of the installed interface physics: 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485. Ground the shield at one end. Confirm the protocol and printer driver configuration in STEP 7 matches the connected device before commissioning. Verify the S7-CPU memory card has capacity for up to 55 kbyte of message texts. Install the configuration package from CD before parameter assignment.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
