Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:ATV71HC25N4
Schneider ATV71HC25N4 Altivar 71 VSD 220kW
Manufacturer: Schneider
Product No.: ATV71HC25N4
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 207000g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Schneider Electric ATV71HC25N4 Altivar 71 Variable Speed Drive
Schneider Electric ATV71HC25N4 | Altivar 71 variable speed drive for complex, high-power machines. Delivers 220 kW continuous (250 kW maximum) motor power with 481 A nominal output current at 380-480V three-phase supply. Integrated EMC filter and forced-air heat sink for demanding industrial applications. Supports asynchronous and synchronous motors. Weight: 207 kg (456.4 lbs).
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | ATV71HC25N4 |
| Product Line | Altivar 71 |
| Product Type | Variable Speed Drive |
| Motor Power (Continuous) | 220 kW (350 HP), 3-phase 380-480V |
| Motor Power (Maximum) | 250 kW (400 HP), 3-phase 380-480V |
| Supply Voltage | 380-480V (-15%/+10%), 3-phase |
| Supply Voltage Limits | 323-528V |
| Supply Frequency | 50-60 Hz ±5% (47.5-63 Hz) |
| Line Current (480V, 220kW) | 320 A |
| Line Current (480V, 250kW) | 357 A |
| Line Current (380V, 220kW) | 396 A |
| Line Current (380V, 250kW) | 444 A |
| Apparent Power (220kW) | 260.6 kVA @ 380V |
| Apparent Power (250kW) | 292.2 kVA @ 380V |
| Nominal Output Current (220kW) | 427 A @ 2.5 kHz |
| Nominal Output Current (250kW) | 481 A @ 2.5 kHz |
| Maximum Transient Current (220kW) | 640 A for 60 s; 704 A for 2 s |
| Maximum Transient Current (250kW) | 721 A for 60 s; 793 A for 2 s |
| Output Frequency | 0.1-500 Hz (adjustable to 599 Hz) |
| Nominal Switching Frequency | 2.5 kHz (adjustable 2.5-8 kHz) |
| Prospective Line Isc | 50 kA |
| EMC Filter | Integrated |
| Heat Sink | Yes (forced air cooling) |
| Display Interface | Graphic terminal (HMI) |
| Control Methods | Sensorless Vector, Vector, V/f, Synchronous |
| Analog Inputs | 2 (AI1 ±10V, AI2 0-20mA/0-10V) |
| Analog Output | 1 (AO1 0-20mA/0-10V) |
| Discrete Inputs | 7 (LI1-LI5 programmable 24VDC, LI6 configurable, PWR safety) |
| Discrete Outputs | 2 relay (R1 NO/NC, R2 NO) |
| Communication | Modbus (2-wire RS485), CANopen |
| Transmission Rates (Modbus) | 4800, 9600, 19200, 38.4 kbps |
| Transmission Rates (CANopen) | 20 kbps to 1 Mbps |
| Speed Accuracy (Closed-Loop) | ±0.01% of nominal speed |
| Torque Accuracy (Closed-Loop) | ±5% |
| Transient Overtorque | 170% for 60 s; 220% for 2 s |
| Braking Torque (with resistor) | ≤150% |
| Insulation Resistance | >1 MOhm at 500V DC for 1 minute |
| Dielectric Strength | 3535V DC (earth to power); 5092V DC (control to power) |
| Protection Class | IP20 |
| Noise Level | 77 dB (86/188/EEC) |
| Operating Temperature | -10°C to +50°C (without derating) |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Altitude | ≤1000 m without derating; 1000-3000 m with 1% derating per 100 m |
| Vibration Resistance | 0.6 gn (10-200 Hz); 1.5 mm peak-to-peak (3-10 Hz) |
| Shock Resistance | 4 gn, 11 ms (EN/IEC 60068-2-27) |
| Dimensions (H x W x D) | 1190 x 595 x 377 mm (46.9 x 23.4 x 14.8 in) |
| Net Weight | 207 kg (456.4 lbs) |
| Gross Weight | 200.49 kg (442.00 lbs) |
| Standards | EN/IEC 61800-3, EN/IEC 61800-5-1, UL Type 1 |
| Certifications | CE, UL, CSA, GOST, NOM 117, C-tick |
Additional Technical Parameters
| Maximum Motor Cable Length (Shielded) | 100 m (328.08 ft) |
| Maximum Motor Cable Length (Unshielded) | 200 m (656.2 ft) |
| Analog Input Sampling Time | 2 ms ±0.5 ms |
| Discrete Input Sampling Time | 2 ms ±0.5 ms |
| STO Response Time | ≤100 ms |
| Relay Output Response Time | 7 ms ±0.5 ms |
| Analog Input Linearity Error | ±0.15% of maximum value |
| Analog Output Linearity Error | ±0.2% |
| Relay Mechanical Life | 100,000 cycles |
| Minimum Switching Current | 3 mA at 24V DC |
Installation Notes
Mount vertically (±10°) in an enclosure with forced air cooling for adequate heat dissipation. Connect 380-480V three-phase supply per local electrical codes. Observe terminal tightening torques: 0.6 N·m for control terminals, 41 N·m for power terminals (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PA/+). Maximum motor cable length is 100 m shielded or 200 m unshielded. Maintain operating temperature within -10°C to +50°C without derating. For altitudes above 1000 m, apply 1% current derating per 100 m. Ensure proper grounding and use the integrated EMC filter for electromagnetic compliance.
FAQs
Q1: What is the motor power rating of this drive?
A1: 220 kW continuous (350 HP) and 250 kW maximum (400 HP) at 380-480V three-phase supply.
Q2: What communication protocols are built in?
A2: Modbus (2-wire RS485) and CANopen.
Q3: Does this drive include an EMC filter?
A3: Yes, the EMC filter is integrated.
Qo'shimcha Texnik Tavsiflar
- DC quvvatlanadigan
- Kichik
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...