Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:MVI56E-MCM
ProSoft MVI56E-MCM Modbus Communication Module PLC Systems
Manufacturer: Allen-Bradley
Product No.: MVI56E-MCM
Product Type: Modbus Communication Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 270g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
ProSoft MVI56E-MCM Modbus Communication Module
The ProSoft MVI56E-MCM is a Modbus communication module designed for industrial automation systems. This module enables reliable data exchange between PLCs and Modbus-compatible devices.
Electrical Specifications
- Backplane Current Load: 800 mA @ 5 Vdc, 3 mA @ 24 Vdc
Environmental Specifications
- Operating Temperature MVI56E-MCM: 0°C to 60°C (32°F to 140°F)
- Operating Temperature MVI56E-MCMXT: -25°C to 70°C (-13°F to 158°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Relative Humidity: 5% to 95% (non-condensing)
Mechanical Specifications
- Weight: 0.27 kg
- Shock Resistance: 30g operational, 50g non-operational
- Vibration Resistance: 5g from 10 to 150 Hz
Key Features
- Protocol Support: Modbus TCP and RTU protocols
- Network Compatibility: Multiple PLC and automation systems
- Installation: Quick-connect terminals for easy setup
- Reliability: Designed for harsh industrial environments
Applications
- PLC to Modbus device communication
- Industrial automation network integration
- Legacy system modernization
- SCADA and HMI system connectivity
Packaging & Shipping
- Includes communication module unit
- Ships via FedEx, UPS, or DHL
FAQ
What protocols does the MVI56E-MCM support?
- The ProSoft MVI56E-MCM supports both Modbus TCP and Modbus RTU communication protocols.
What is the operating temperature range?
- Standard version: 0°C to 60°C. Extended version (MCMXT): -25°C to 70°C.
How much backplane current does it require?
- It requires 800 mA at 5 Vdc and 3 mA at 24 Vdc from the PLC backplane.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Masofadan Texnik Xizmat Fabrika Avtomatizatsiyasi Xarajatlarini Kamaytirishi Mumkinmi?
Ishlab chiqarish korxonalari an'anaviy joyida PLC texnik xizmatiga millionlab mablag‘ yo‘qotadi. Ushbu maqolada maydo...
-
Favqulodda Import Qilingan Zaxira Qismlar Rejalashtirilmagan Zavod To‘xtashlarini To‘xtata Oladimi?
Rejalashtirilmagan boshqaruv tizimi nosozliklari sanoat korxonalariga soatiga 500 000 dollargacha zarar yetkazadi, am...
-
Hamkorlikdagi DCS yuk javob kechikishlarini 0,4 soniyadan pastga qisqartira oladimi?
Ushbu maqola issiqlik elektr stantsiyalarida ko‘p birlikli hamkorlik boshqaruvi uchun ierarxik DCS arxitekturasini ta...
-
PLC kabinet issiqdan qanday qilib nosozlikni to'xtatish mumkin?
Ushbu maqola boshqaruv shkaflaridagi yashirin issiqlik avtomatlashtirishdagi tasodifiy nosozliklarning 68% sababchisi...
-
PLC qayta yozilishi to‘liq apparat yangilanishining o‘rnini bosadimi?
Ushbu maqola kross-brend PLC kod migratsiyasi orqali eski ishlab chiqarish liniyalarida to‘liq apparat almashtirish o...
-
Emerson eski fabrikalarda ISO 50001 ma'lumot bo'shliqlarini to'ldira oladimi?
Ushbu maqola an’anaviy PLC va DCS tizimlarining ISO 50001 talablariga muvofiq nozik energiya monitoringi yetishmaslig...
