Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:MTL5061
MTL5061 Fire Smoke Detector Interface - MTL Instruments
Manufacturer: MTL
Product No.: MTL5061
Product Type: Detector Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
MTL5061 Fire & Smoke Detector Interface
The MTL5061 from MTL Instruments is a loop-powered dual-channel interface designed for fire and smoke detectors in hazardous areas. This specialized unit provides reliable signal transmission from detectors to safe-area monitoring systems.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5061
- Product Type: Fire & Smoke Detector Interface
- Channels: Two independent channels
- Power Type: Loop-powered operation
- Current Range: 1 to 40mA nominal
- Response Time: 30ms maximum
Hazardous Area Certification
- Detector Location: Zone 0, IIC, T4-T6 hazardous area
- Division Rating: Division 1, Group A hazardous location
- The MTL5061 maintains intrinsic safety for fire detection systems
- It enables safe operation of detectors in explosive atmospheres
Electrical Performance
- Current Range: 1 to 40mA nominal operating range
- Transfer Accuracy: Better than 400µA at 20°C
- Temperature Drift: <10µA/°C (-20 to 60°C)
- Response Time: Settles within 30ms to 500µA of final value
- Quiescent Current: <400µA per channel at 24V DC
Output Characteristics
- Maximum Output Voltage: 28V from 300Ω
- Minimum Output Voltage: Lower of Vin – (0.38 x mA) – 2V or 21V – (0.35 x mA)
- Automatic voltage calculation based on current draw
- Stable output performance across operating range
Power Requirements
- Loop Supply Voltage: 6 to 35V DC operating range
- Power Dissipation: 0.7W at 24V with 40mA signal per channel
- Maximum Dissipation: 1.2W at 35V with 40mA signal per channel
- Loop-powered design simplifies installation
Terminal Configuration
- Channel 1 Output: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
- Channel 1 Input: Terminal 11 (Input –ve), Terminal 12 (Input +ve)
- Channel 1 Earth: Terminal 3 for leakage detection
- Channel 2 Output: Terminal 4 (Output –ve), Terminal 5 (Output +ve)
- Channel 2 Input: Terminal 8 (Input –ve), Terminal 9 (Input +ve)
- Channel 2 Earth: Terminal 6 for leakage detection
Safety Parameters
- Safety Voltage: 28V maximum
- Internal Resistance: 300Ω
- Safety Current: 93mA maximum
- Isolation Voltage: Um = 250V rms or DC
- Comprehensive protection for fire safety applications
Frequently Asked Questions
-
What detectors is the MTL5061 designed for?
It interfaces with conventional fire and smoke detectors in hazardous areas. -
How does earth fault detection work?
Optional 'non-fail' detection via MTL4220 unit allows continued operation during faults. -
What is the response time for detector signals?
It settles within 30ms to within 500µA of the final value. -
Is reverse polarity protection included?
Yes, the input circuit has integrated reverse polarity protection.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...