Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:MTL5014
MTL5014 Dual Relay Interface - MTL Instruments
Manufacturer: MTL
Product No.: MTL5014
Product Type: Vibration Sensor Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
MTL5014 Dual Relay Interface
The MTL5014 from MTL Instruments provides sophisticated control for hazardous area applications. This single-channel interface enables two safe-area loads to be controlled by one switch or proximity detector. It offers advanced features including line fault detection, phase reversal, and dual relay outputs for maximum flexibility.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5014
- Product Type: Dual Relay Interface
- Channels: One input channel
- Outputs: Two changeover relays
- Response Time: 10ms maximum
- Supply Voltage: 20 to 35V DC
Hazardous Area Certification
- Switch Location: Zone 0, IIC, T6 hazardous area
- Detector Location: Zone 0, IIC, T4-T6 with certification
- Division Rating: Division 1, Group A hazardous location
- The MTL5014 maintains intrinsic safety for connected sensors
Input Specifications
- Input Standard: NAMUR/DIN 19234 for proximity detectors
- Sensor Voltage: 7.0 to 9.0V from 1kΩ ±10% source
- Normal Phase: Output energizes if Iin >2.1mA or Rin <2kΩ
- Reverse Phase: Output de-energizes under same conditions
- Hysteresis: 250µA typical for stable switching
- Phase Reversal: User selectable for output 1
Relay Output Characteristics
- Relay Type: Two single-pole changeover contacts
- Contact Rating AC: 250V AC, 2A, cosø >0.7
- Contact Rating DC: 40V DC, 2A, resistive load
- Contact Life: 300,000 operations at maximum load
- Response Time: 10ms maximum for fast control
- Note: Reactive loads require adequate suppression
Line Fault Detection (LFD)
- LFD Mode: User selectable - Off or On
- Open Circuit Alarm: Activated if Iin < 100µA
- Short Circuit Alarm: Activated if Iin > 6.5mA
- Fault Response: De-energizes Output 1 relay
- Contact Input: Requires 500Ω-1kΩ series and 20kΩ-25kΩ parallel resistors
Terminal Configuration
- Input: Terminal 1 (Input –ve), Terminal 2 (Input +ve)
- Earth Leakage: Terminal 3 for detection
- Output 1: Terminal 10 (NC), 11 (Common), 12 (NO)
- Output 2: Terminal 7 (NC), 8 (Common), 9 (NO)
- Power Supply: Terminal 13 (Supply –ve), 14 (Supply +ve)
Power Requirements
- Supply Voltage: 20 to 35V DC operating range
- Current Consumption: 45mA at 24V maximum
- Power Dissipation: 1.1W at 24V maximum
- Power Failure Protection: Built-in safety features
Safety Parameters
- Safety Voltage: 10.5V maximum
- Internal Resistance: 800Ω
- Safety Current: 14mA maximum
- Maximum Voltage: Um = 250V rms or DC
Frequently Asked Questions
-
How many loads can the MTL5014 control?
It can control two independent safe-area loads from one hazardous area input. -
What is the line fault detection capability?
It detects both open circuits (<100µA) and short circuits (>6.5mA) in field wiring. -
Can I reverse the output logic?
Yes, Output 1 features user-selectable phase reversal operation. -
What sensors are compatible?
It works with NAMUR proximity detectors and switches in hazardous areas.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?