Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:MTL5040
MTL Instruments MTL5040 Dual Channel Interface
Manufacturer: MTL
Product No.: MTL5040
Product Type: Repeater Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
MTL5040 Bidirectional Signal Interface
The MTL5040 from MTL Instruments provides versatile signal handling for hazardous areas. This dual-channel unit combines transmitter power supply with signal driving capabilities. It handles bidirectional communication between safe and hazardous areas with high precision and speed.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5040
- Product Type: Bidirectional Signal Interface
- Channels: Two independent channels
- Channel 1 Function: Transmitter Power & Repeater
- Channel 2 Function: Signal Driver to Hazardous Area
- Response Time: 250µs typical
- Supply Voltage: 20 to 35V DC
Hazardous Area Certification
- Equipment Location: Zone 0, IIC, T4-T6 hazardous area
- Division Rating: Division 1, Group A hazardous location
- The MTL5040 maintains intrinsic safety for both channels
- It enables safe bidirectional signal transmission in explosive atmospheres
Channel 1 - Transmitter Repeater
- Input Signal: 0 to 24mA from hazardous area transmitter
- Transmitter Voltage: 16.5V at 20mA power supply
- Output Signal: 4 to 20mA to safe area (0-24mA range)
- Load Resistance: 0 to 550Ω maximum
- Input Terminals: Terminal 1 (Input –ve), Terminal 2 (Input +ve)
- Output Terminals: Terminal 11 (Output –ve), Terminal 12 (Output +ve)
Channel 2 - Signal Driver
- Input Signal: 4 to 20mA from safe area controller
- Output Signal: 4 to 20mA to hazardous area load
- Load Resistance: 550Ω maximum (11V at 20mA)
- Input Voltage Drop: <4V at 20mA
- Input Terminals: Terminal 8 (Input –ve), Terminal 9 (Input +ve)
- Output Terminals: Terminal 4 (Output –ve), Terminal 5 (Output +ve)
Performance Specifications
- Transfer Accuracy: Better than 20µA at 20°C
- Typical Accuracy: Typically 5µA
- Temperature Drift: <1µA/°C
- Response Time: Settles within 250µs typical to 10% of final value
- Circuit Ripple: <40µA peak-to-peak
- Output Resistance: >2MΩ for both channels
Power & Isolation
- Supply Voltage: 20 to 35V DC
- Current Consumption: 95mA at 24V with 20mA signals
- Power Dissipation: 1.6W at 24V maximum
- Isolation: 250V AC between all circuits
- Status Indicator: Green LED for power monitoring
Terminal Configuration
- Power Supply: Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)
- Channel 1 Transmitter: Terminals 1-2 (Input), Terminals 11-12 (Output)
- Channel 2 Driver: Terminals 8-9 (Input), Terminals 4-5 (Output)
- Clear terminal identification ensures correct wiring
Safety Parameters
- Safety Voltage: 28V maximum
- Internal Resistance: 300Ω
- Safety Current: 93mA maximum
- Maximum Voltage: Um = 250V rms or DC
Frequently Asked Questions
-
What makes the MTL5040 different from other repeaters?
It provides bidirectional capability - both powering transmitters and driving signals to hazardous areas. -
What load capacity does each channel have?
Both channels support loads up to 550Ω with full signal accuracy. -
How fast is the signal response?
The unit typically settles within 250 microseconds to 10% of final value. -
Is this suitable for controller output signals?
Yes, Channel 2 specifically handles 4-20mA signals from controllers to hazardous area loads.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...