Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:T9402
ICS Triplex T9402 Digital Input Module 16 Channel 24V
Manufacturer: ICS Triplex
Product No.: T9402
Product Type: Digital Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The ICS Triplex T9402 is a 16‑channel isolated digital input module for the Trusted TMR system. It accepts 0–32 Vdc inputs at 6.5 mA per channel, making it suitable for field contact monitoring, switch status, and limit sensing in safety‑critical applications. The module delivers deterministic scan times configurable for simplex (0.924 ms), dual (1.676 ms), or triple (2.453 ms) redundancy configurations.
Core Advantages
Flexible Redundancy Configuration
Supports simplex, dual, or triple input configurations with predictable scan times. Choose the redundancy level that matches your safety integrity requirements—0.924 ms for simplex, 1.676 ms for dual, or 2.453 ms for triple.
Fully Isolated Channels
All 16 channels are galvanically isolated, protecting the backplane from field transients and ensuring reliable operation in noisy industrial environments.
Low Power Consumption
Draws only 4.0 W (260 mA at 24V), minimising heat generation and reducing chassis cooling requirements.
Specifications
| Parameter | Value |
|---|---|
| Supply Voltage | 18–32 Vdc |
| Maximum Current | 260 mA |
| Power Consumption | 4.0 W |
| Heat Dissipation | 4.0 W (13.6 BTU/hr) |
| Input Voltage Range | 0–32 Vdc |
| Input Current | 6.5 mA |
| Number of Channels | 16 (isolated) |
| Scan Time (Simplex) | 0.924 ms |
| Scan Time (Dual) | 1.676 ms |
| Scan Time (Triple) | 2.453 ms |
| Certifications | ATEX, IECEx, HazLoc, Ordinary Location |
| Weight | 340 g |
Installation Tips
Redundancy Planning
Select simplex, dual, or triple configuration based on your SIL requirement and available slots. Triple configuration uses three T9402 modules for 2‑out‑of‑3 voting. Scan time scales linearly with redundancy level.
Input Wiring
Connect field devices (pushbuttons, limit switches, proximity sensors) to the isolated input terminals. Each channel accepts 0–32 Vdc at 6.5 mA. Use shielded cables for long field runs to minimise noise pickup.
Channel Isolation
Each input is independently isolated from the backplane and from other channels. This prevents ground loops and protects the system from field wiring faults.
Why Choose T9402?
Delivers 16 isolated digital inputs in a compact, low‑power package. The deterministic scan times allow precise timing for safety logic execution. Supports flexible redundancy configurations to match any SIL level. Certified for hazardous areas and compatible with all ICS Triplex Trusted chassis. Ideal for emergency shutdown, fire & gas, and burner management systems.
FAQs
Q1: What determines the scan time I should use?
A1: The scan time depends on your system's redundancy configuration. Simplex (0.924 ms) for single modules, dual (1.676 ms) for redundant pairs, and triple (2.453 ms) for full TMR with 2‑out‑of‑3 voting.
Q2: Can I mix input voltage levels on different channels?
A2: Yes. Each channel accepts any voltage from 0 to 32 Vdc independently, thanks to full channel‑to‑channel isolation.
Q3: What is the 6.5 mA input current used for?
A3: The 6.5 mA is the wetting current that flows through the field contact. It helps clean switch contacts and ensures reliable low‑resistance connections, especially for dry contact inputs.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
-
How to Quantify and Fix Allen‑Bradley HMI Flickering in Cement Plants?
This technical article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering in cement plants...
-
How to Fix HMI Flickering Caused by Power Noise and Vibration?
This article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering faults in cement productio...
-
Stop 68% of DCS Faults with Proven Transmitter Matching Rules?
This article presents field-verified solutions for optimizing communication between Rosemount transmitters and Emerso...
-
What Does Poor PLC Backup Cost Your Paper Plant?
This technical article presents quantified backup and recovery standards for GE Fanuc RX7i PLCs in high-capacity pape...