Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:FS-TSFIRE-1624
Honeywell Safety Manager FS-TSFIRE-1624 Fire Input Module
Manufacturer: Honeywell
Product No.: FS-TSFIRE-1624
Product Type: Input FTA Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Honeywell TSFIRE-1624 Fire Detector Input FTA Module
The Honeywell FS-TSFIRE-1624 and FC-TSFIRE-1624 are safe Field Termination Assembly (FTA) modules. They interface digital fire detectors with the Safety Manager's SAI-1620m analog input module in Class I Division 2 hazardous locations.
Core Functions
- Safe Power Supply: Provides voltage-current-limited power to each detector, meeting Class I Division 2 standards.
- Signal Conversion: Converts 24 V DC fire detector inputs to levels suitable for the SAI-1620m module.
- Global Reset: Enables a global reset function for all connected fire sensors simultaneously.
Technical Specifications
- Brand & Model: Honeywell FS-TSFIRE-1624 / FC-TSFIRE-1624.
- Input Channels: 16 channels for fire detector connection.
- Power Supply: 24 V DC external, with a tolerance of +25% / -15%.
- Current: Maximum 570 mA (with EOL), typical 70 mA (no load).
- Channel Voltage: Typical 20.5 V DC with EOL resistor installed.
- Channel Resistance: 680 Ω ±5% per channel.
- Wire Termination: Screw terminals accept up to 2.5 mm² (AWG 14) wire. Tightening torque: 0.5 Nm.
- EOL Resistor: 4.7kΩ ±5% (0.25 W) recommended.
- Dimensions: 170 mm (L) × 70 mm (W) × 64 mm (H). Mounts on DIN rail.
Packaging & Shipping
- Package Includes: One FTA module and installation guide.
- Shipping: Orders ship via FedEx, UPS, or DHL.
FAQ
What does the TSFIRE-1624 module do?
- The Honeywell TSFIRE-1624 is a safe interface module. It connects and powers fire detectors in hazardous areas for the Safety Manager system.
How many detectors connect to one module?
- You can connect up to 16 detectors to a single FS-TSFIRE-1624 module.
What are the safety approvals?
- The module holds major safety certifications, including UL, CSA, FM, TUV, and CE.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...
