Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:F3330
HIMA F3330 Output Module Safety Related 8 Fold AK1-6
Manufacturer: HIMA
Product No.: F3330
Product Type: Digital Output Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The F3330 (also designated as F 3330) is an 8-fold safety-related digital output module manufactured by HIMA for high-integrity safety systems up to Requirement Class AK 1...6. It provides eight short-circuit-proof outputs capable of driving resistive or inductive loads up to 500 mA (12 W) and lamp loads up to 4 W. Featuring integrated safety shutdown, safe electrical isolation, and undervoltage tripping at ≤ 16 V, the F3330 prevents output signals upon L- supply breakage. Occupying 4 TE width and weighing 0.45 kg, it delivers reliable field actuation in SIL-rated control panels.
Core Technical Advantages
- High Safety Integrity (AK 1...6): Designed for critical safety applications requiring safe isolation and integrated safety shutdown.
- Short-Circuit Proof Outputs: 8 output channels feature built-in short-circuit protection for loads up to 500 mA (12 W).
- Comprehensive Voltage Protection: Features automated undervoltage tripping at ≤ 16 V and output cutoff on L- supply failure.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand & Manufacturer | HIMA |
| Model Designation | F3330 (F 3330) |
| Product Type | 8-Fold Output Module (Safety Related) |
| Requirement Class Rating | AK 1 ... 6 |
| Output Capacity per Channel | 500 mA (12 W) Resistive/Inductive; 4 W Lamp Load |
| Short-Circuit Protection | Short-Circuit Proof (k) |
| Max Internal Voltage Drop | 2 V at 500 mA load |
| Admissible Line Resistance | Max. 11 Ohm (In + Out) |
| Undervoltage Tripping | At ≤ 16 V |
| Operating Power Requirements | 5 V DC = 110 mA / 24 V DC = 180 mA (plus load current) |
| Safety Features | Integrated safety shutdown, safe isolation, zero signal on L- break |
| Space Requirement | 4 TE (Width) |
| Operating Temperature | 0°C to +60°C |
| Product Net Weight | 0.45 kg (450 g) |
Industrial Applications
- Emergency Shutdown (ESD) Systems: Actuates safety solenoids and trip valves in critical process plants.
- Burner Management Systems (BMS): Drives fuel safety shut-off valves requiring AK1-6 compliance.
- Hazardous Signal Annunciation: Controls pilot lamps and alarm relays with integrated short-circuit isolation.
Wiring & Installation
- Module Insertion: Mount the 4 TE module into the designated HIMA subrack slot until fully seated.
- Line Resistance Check: Verify that combined supply and return wire resistance does not exceed 11 Ohms.
- Field Load Wiring: Wire 24 V DC actuators or indicators to output terminals observing polarity.
Engineering Advantages
- Low Internal Losses: Maximum 2 V voltage drop at full 500 mA load minimizes thermal dissipation.
- Compact Enclosure: Requires only 4 TE of rack width to save cabinet backplane space.
- Fail-Safe Architecture: Guarantees output drop-out when L- supply is interrupted or voltage falls below 16 V.
Technical FAQs
Q1: What load ratings does each output channel of the HIMA F3330 support?
A1: Channels support 500 mA (12 W) resistive/inductive loads or up to 4 W lamp loads.
Q2: At what voltage level does undervoltage tripping occur on the F3330?
A2: The module trips and shuts down outputs when supply voltage drops to ≤ 16 V.
Q3: What is the maximum line resistance permitted for field wiring?
A3: Total admissible line resistance (in + out combined) is maximum 11 Ohms.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...