Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:HIEE205012R1
HIEE205012R1 UNC4672A V1 ABB Measuring Interface Unit
Manufacturer: ABB
Product No.: HIEE205012R1
Product Type: Interface Unit
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 550g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
ABB UNC4672A V1 Measuring Interface Unit
The ABB UNC4672A V1 is a compact measuring interface unit for industrial automation. It converts digital and analog input signals into stable 4-20 mA outputs and Modbus RTU streams, protecting control systems from field noise.
Key Advantages
- Galvanic Isolation: Prevents ground loops and signal interference.
- Modbus RTU: Supports direct RS-485 integration and remote diagnostics.
- IP54 Housing: Ensures durable operation in harsh plant environments.
Technical Specifications
| Input / Output | Digital & Analog Input / 4-20 mA Output |
| Communication | Modbus RTU (RS-485) |
| Power Supply | 90-240 V AC (50/60 Hz) |
| Ratings & MTBF | IP54 / > 200,000 hours |
| Environment | -20°C to +50°C / 5% to 95% RH (non-condensing) |
| Physical Details | 150 mm x 250 mm x 45 mm / 0.55 kg / Wall-mounted |
Quick Installation
- Mounting: Wall-mount vertically with 50 mm clearance for cooling.
- Wiring: Use shielded twisted-pair cables; ground the shield at one point.
- Bus Network: Install a 120 Ω termination resistor at the RS-485 bus ends.
Technical FAQs
Q1: How to fix Modbus connection faults?
A1: Check that baud rate, parity, and station ID match. Ensure the 120 Ω resistor is installed.
Q2: Is external loop power required for the 4-20 mA output?
A2: No. The output loop is actively powered by the unit's 90-240 V AC supply.
Q3: Can it operate in high-humidity areas?
A3: Yes. It runs reliably in non-condensing environments up to 95% relative humidity.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can Staged Hardware Upgrades Eliminate Unplanned Downtime?
This technical article examines the hidden risks of ageing Allen‑Bradley PLC and DCS hardware in continuous process e...
-
Is Protocol Conversion Key to Unified Factory Automation?
Mixed-vendor PLC and DCS environments create significant operational inefficiencies and unplanned downtime in modern ...
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
