Product Overview
The GE Fanuc IC697ACC644 is a heavy-duty rack fan assembly engineered specifically for the Series 90-70 automation system. This critical cooling component ensures optimal thermal management within the PLC rack, preventing hardware overheating and extending the lifespan of sensitive electronic modules.
This assembly features a dual-fan setup, providing redundant and high-volume airflow across the rack backplane. Operating on a standard 24 VDC supply, each fan consumes only 6.7 watts, making it an energy-efficient solution for 24/7 industrial operations. The rugged design is built to withstand extreme environments, with an impressive operating temperature range from -28°C to +70°C.
Technical Specifications
| Technical Parameter | Detail Specification |
|---|---|
| Input Voltage | 24 VDC |
| Fan Configuration | Dual-Fan System |
| Current Draw | 0.28 Amps per Fan |
| Power Consumption | 6.7 Watts per Fan |
| Filter Rating | 30 Pores Per Inch (PPI) |
| Weight | 1.8 kg (Approximately 4 lbs) |
Key Performance Features
- Advanced Dust Filtration: Equipped with a 30 PPI polyurethane foam filter to ensure clean airflow and protect internal components from particle buildup.
- Flame-Retardant Materials: The filter retainer is constructed from UL94V-0 rated plastic, adhering to strict industrial safety standards.
- Extreme Temperature Resilience: Reliable performance in harsh climates, capable of operating in sub-zero temperatures down to -28°C.
- Easy Maintenance: The assembly is designed for quick access, allowing for rapid filter inspection or replacement to maintain peak cooling efficiency.
Installation & Maintenance
The IC697ACC644 is designed to mount directly to the Series 90-70 rack frame. For maximum effectiveness, ensure that the intake and exhaust areas are free from obstruction. Regular cleaning of the polyurethane foam filter is recommended to maintain the rated airflow and prevent current draw increases due to motor strain.
Technical FAQs
Q1: Does this fan assembly require a separate power supply?
A1: The assembly requires a 24 VDC source, which can typically be drawn from the PLC power supply or an external industrial DC supply.
Q2: Can the fans be replaced individually?
A2: While the IC697ACC644 is sold as a complete dual-fan assembly for guaranteed balance and airflow, the internal fans are standard industrial components.
Q3: Is the filter washable?
A3: Polyurethane foam filters of this type can often be cleaned with low-pressure air or mild soap and water, but they should be completely dry before re-installation.
Condition: New & Original in Factory Packing
Warranty: 1 Year Comprehensive Warranty
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...