Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:IC693PWR325
GE Fanuc IC693PWR325 Power Supply 24/48VDC Series 90-30 PLC
Manufacturer: General Electric
Product No.: IC693PWR325
Product Type: Power Supply Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 900g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The GE Fanuc IC693PWR325 is a versatile DC Input Power Supply module specifically engineered for the Series 90-30 PLC system. Designed to accommodate a broad input range from 24 to 48 Volts DC, this 30-Watt module provides reliable power distribution across the PLC backplane. The IC693PWR325 is essential for powering CPU modules, relay circuits, and isolated input modules, making it a critical component for industrial automation environments requiring flexible DC power integration.
Technical Configuration
Robust power architecture for Series 90-30 factory floor and cabinet installations:
- Brand: GE Fanuc / Emerson
- Model Number: IC693PWR325
- Input Voltage Range: 24 to 48 VDC
- Total Load Capacity: 30 Watts
- Output Current: 0.8 Amperes
- Peak Inrush Current: 4 Amperes (100 ms peak)
- Protection: Overvoltage protection on 5 VDC output
- Battery: Integrated 1.45 Amp-hour capacity
Technical Specifications
| Requirement | Detailed Specification |
|---|---|
| Unit Weight | Approximately 0.9 kg |
| Output Voltages | 5VDC (CPU), 24VDC (Relay), 24VDC (Isolated) |
| Torque Rating | 12 lb-in (Terminal Screws) |
| Operating Temp (Battery) | 0 to 85°C |
| Mounting Method | Bolt/Screw mount for factory floor enclosures |
| Certifications | CE and UL Compliant |
Engineering Advantages
The GE Fanuc IC693PWR325 stands out for its multi-rail power delivery, providing simultaneous 5VDC for logic and dual 24VDC outputs for relay and isolated input requirements. Despite its robust performance, the unit maintains a manageable weight of approximately 0.9 kg. A key safety feature is its overvoltage protection on the 5VDC rail, which safeguards sensitive CPU components from voltage spikes. Additionally, the integrated 1.45 Amp-hour battery provides essential memory backup during power loss, while its 12 lb-in torque rating ensures secure, vibration-resistant wiring connections in industrial cabinets.
Technical FAQs
Q1: What is the benefit of having "isolated" 24VDC output?
A1: The isolated 24VDC output is designed to power input modules while keeping the electrical noise of field devices separate from the sensitive internal logic of the PLC, improving system stability.
Q2: Can I use this module in a 12VDC system?
A2: No. The IC693PWR325 requires a minimum of 24 VDC to operate correctly. Applying voltage below the 24V threshold will likely prevent the power supply from initializing its output rails.
Q3: How often should the internal battery be replaced?
A3: While the battery is rated for a wide temperature range, typical replacement cycles are every 1-2 years depending on ambient temperature and the frequency of power cycles to ensure memory retention.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can PLC and DCS Replace Dedicated TSI Protection?
This article examines why critical rotating machinery requires independent safety barriers separate from standard PLC...
-
Can Bently Nevada TSI Prevent Turbine Trips in Automation?
This technical article examines why standard PLC and DCS process monitoring fails to detect early-stage rotating mach...
-
Can Staged Hardware Upgrades Eliminate Unplanned Downtime?
This technical article examines the hidden risks of ageing Allen‑Bradley PLC and DCS hardware in continuous process e...
-
Is Protocol Conversion Key to Unified Factory Automation?
Mixed-vendor PLC and DCS environments create significant operational inefficiencies and unplanned downtime in modern ...
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...