Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:PR6426/000-140
Epro PR 6426/000-140 Reverse Mount Sensor
Manufacturer: Emerson
Product No.: PR6426/000-140
Product Type: Eddy Current Sensor
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The PR 6426/000-140 represents the pinnacle of non-contact displacement technology for critical rotating machinery. Designed by Epro (Emerson), this eddy current sensor excels in measuring turbine shaft vibration and axial thrust with micron-level precision. Its unique reverse-mount geometry allows for external installation into confined internal spaces, making it the go-to solution for high-density power plant and petrochemical applications.
Technical Configuration
Integrated Signal Conversion
Unlike traditional probes requiring external drivers, this unit features the Con021 integrated electronics. It converts displacement directly into a robust 4-20 mA industrial signal, simplifying the hardware loop and reducing potential failure points across the signal chain.
Reverse Mount Engineering
The threaded body is optimized for "outside-in" installation. This allows technicians to calibrate the sensor gap from the exterior of the machine housing, significantly reducing downtime and labor costs during critical maintenance intervals.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Measuring Range | 2.0 mm |
| Output Signal | 4 to 20 mA DC |
| Linearity Error | < ±1.5% |
| Frequency Response | 0 Hz to 5,000 Hz |
| Supply Voltage | 18 to 30 V DC |
| Operating Temp | -20°C to +120°C |
| Cable Length | 5 Meters (Standard) |
Installation Guide
For optimal accuracy, set the sensor air gap to the 12 mA midpoint when the target is at rest. The PR 6426/000-140 requires a target area at least three times the probe diameter to avoid edge interference. Ensure the 5-meter cable maintains a minimum bend radius of 30 mm to protect signal integrity and prevent shielding fatigue.
Engineering Advantages
This sensor provides laboratory-grade precision in harsh industrial zones. Its PEEK-protected tip resists oil, steam, and chemical corrosion, ensuring a stable 12-month operation cycle in temperatures up to 120°C. By outputting a standardized 4-20 mA signal, it integrates seamlessly into existing PLC or DCS architectures without the need for proprietary rack-based monitors.
Technical FAQs
Q1: Can this sensor be installed while the machine is running?
A1: While the physical mount allows external access, for safety and precise gap calibration (setting the 12 mA baseline), we recommend installation during machine standstill or slow-roll conditions.
Q2: What happens if the cable is cut or shortened?
A2: The PR 6426/000-140 is factory-calibrated with its specific 5-meter cable. Altering the length will change the system impedance and compromise the 1.5% linearity specification.
Q3: Is a separate transmitter required?
A3: No. The integrated Con021 design means the sensor body handles all signal processing, outputting 4-20 mA directly to your control system terminal.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...