Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:V18345-2021421001
Double Acting Positioner 4-20 mA | New ABB V18345
Manufacturer: ABB
Product No.: V18345-2021421001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
ABB V18345-2021421001 TZIDC Electro-Pneumatic Positioner
The V18345-2021421001 (also cataloged as the V18345 Electro-Pneumatic Positioner) is a TZIDC intelligent positioner in a varnished aluminium case rated IP 65 (NEMA 4X). It accepts a 4-20 mA two-wire HART input and provides double-acting fail-safe output, with ATEX Ex II 2 G EEx ib II C T6 explosion protection. Unit weight is 1.7 kg.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | V18345-2021421001 |
| Brand | ABB |
| Product Type | TZIDC Electro-Pneumatic Positioner |
| Housing | Aluminium, IP 65 / NEMA 4X, RAL 9005 matte black |
| Weight | 1.7 kg |
| Input Signal | 4 to 20 mA, two-wire, HART via FSK module |
| Explosion Protection | ATEX Ex II 2 G EEx ib II C T6 |
| Output Function | Double acting, fail safe |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h / 0.015 scfm |
| Pneumatic Connections | Threads G 1/4 or 1/4-18 NPT |
| Electrical Connections | Cable: Thread 1/2-14 NPT |
| Digital Input | 0-5 V DC logical 0; 11-30 V DC logical 1 |
| Digital Output | 5 to 11 V DC, DIN 19234/NAMUR |
| Position Feedback | Plug-in analog module, 4-20 mA |
Signal and Characteristic Curve Control
The V18345-2021421001 uses two-wire technology with a nominal 4-20 mA signal range, where 4 mA corresponds to 0 % and 20 mA to 100 % position. Split range operation is freely selectable with a minimum range of 20 % (3.2 mA) and a recommended range above 50 % (8.0 mA). The signal action is configurable as direct (4-20 mA = position 0-100 %) or reverse (20-4 mA = position 0-100 %). The travel characteristic is selectable as linear, equal percentage at 1:25 or 1:50, 25:1 or 50:1, or user-configurable with 20 reference points. The digital input activates a selected protective function when the 24 V DC signal drops below 10 V DC; selectable functions include move to 0 %, move to 100 %, hold last position, disable local configuration, disable local configuration and operation, or disable any access. The HART FSK module enables remote configuration through the 4-20 mA loop. The digital output follows the DIN 19234/NAMUR control circuit at 5-11 V DC.
Field Installation Guidelines
Mount the positioner to a linear actuator per DIN/IEC 534 / NAMUR or to a rotary actuator per VDI/VDE 3845 using the mechanical position indicator. Verify the hazardous area classification matches ATEX Ex II 2 G EEx ib II C T6 and confirm the input loop is intrinsically safe before wiring. Confirm the 1.7 kg unit is supported by the actuator mounting bracket. Connect the 4-20 mA HART input through the 1/2-14 NPT cable entry and the air supply through the G 1/4 or 1/4-18 NPT port. Verify supply air is dry and oil-free within 1.4 to 6 bar. For double-acting actuators, connect both pneumatic outputs and verify fail-safe action before pressurizing. Route signal wiring separately from AC power conductors and maintain the case seal for IP 65 / NEMA 4X integrity. Set split range, characteristic curve, and digital input function through the local panel or HART configuration before placing the loop in service.
Frequently Asked Questions
Q: What is the explosion protection rating of the V18345-2021421001?
A: ATEX Ex II 2 G EEx ib II C T6.
Q: What is the output function and supply pressure range?
A: Double acting, fail safe; supply pressure 1.4 to 6 bar (20 to 90 psi).
Q: What is the minimum split range and recommended split range?
A: Minimum range 20 % (3.2 mA); recommended range above 50 % (8.0 mA).
Qo'shimcha Texnik Tavsiflar
- Kumush
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...
