Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1794-ACNR15
Allen-Bradley FLEX IO 1794-ACNR15 5 Mbps Network Module
Manufacturer: Allen-Bradley
Product No.: 1794-ACNR15
Product Type: Adapter Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 210g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The 1794-ACNR15 is a high-reliability, Redundant ControlNet Adapter Module from Allen-Bradley's dependable FLEX IO product line. Serving as an intelligent network interface component, this lightweight 0.21 kg module bridges distributed factory-floor I/O modules directly to a master Programmable Logic Controller (PLC) over a deterministic ControlNet network link. Featuring dual physical BNC ports, it maintains uninterrupted communication tokens across a redundant media loop, ensuring continuous uptime for critical process lines and heavy industrial machinery.
Core Features
- Redundant Media Interface: Equipped with two ControlNet BNC ports to provide active communication path protection against single-point cable failures.
- High Backplane Capacity: Delivers a maximum of 640 mA of Flexbus output current to seamlessly power high-density local discrete or analog I/O racks.
- Superior Galvanic Isolation: Features a high 850V DC electrical isolation barrier to shield sensitive backplane logic components from field surges.
- Excellent Noise Immunity: Built-in 60 dB noise rejection combined with 100 dB common mode rejection ensures reliable data transfers in high EMI environments.
Technical Specifications
| Parameter | Data |
|---|---|
| Model / Catalog Number | 1794-ACNR15 (FLEX IO Architecture) |
| Network Interface Profile | Redundant ControlNet Media Adapter |
| Physical Connections | 2 x ControlNet BNC Coaxial Ports (Channel A and Channel B) |
| Data Transfer Rate | 5 Mbps (Deterministic clock speed) |
| External Power Requirement | 24V DC nominal (19.2 to 31.2V DC allowable window) |
| Current / Power Consumption | 400 mA max from external supply / 3.4W max power dissipation @ 19.2V |
| Inrush Current Rating | 23 Amps for a 2 millisecond startup window |
| Max Flexbus Output Current | 640 mA maximum logic supply link |
| System Precision Performance | ±0.1% full-scale accuracy tracking with a 10 ms quick response time |
| Module Net Weight | 0.21 kg (0.46 lbs) |
| Operating Ambient Range | −20 to 55 °C (−4 to 131 °F) extended thermal rating |
| Harmonized Tariff Code | 8537101190 |
Engineering & Installation Guide
- Mounting Support & Weight Limits: At a compact net weight of 0.21 kg, this adapter mounts easily onto a standard TS35 DIN rail. Ensure the rail configuration is free from heavy physical shock to protect the interconnected flex backplane lines from loose contacts.
- DIP Switch Station Addressing: Set the distinct ControlNet node address using the dual rotary or hardware DIP switches on the adapter module before snapping the unit onto the DIN rail framework.
- Dual Coaxial Network Tap Lines: Connect both standard RG-6 coaxial cables to ports A and B using the appropriate 1794 network taps. Keep a maximum wire cross-section of 3.31 mm² (12 AWG) in mind for auxiliary terminal interfaces.
- Inrush Current Mitigation: Ensure your source 24V DC line supply is adequately sized. The adapter triggers a sharp 23A inrush current spike for 2 ms during hot bootups, which can cause undersized fast-acting power supplies to trip out.
- Thermal Layout Space: Although this compact unit relies on passive convection cooling up to 55 °C, it generates 15.7 BTU/hr under full load. Ensure adequate ventilation gaps are maintained around your cabinet enclosure layout.
Technical FAQs
Q1: How does the redundant media protocol function across ports A and B on the 1794-ACNR15 module?
A1: The module processes incoming data tokens over both BNC channels simultaneously. If a physical break occurs on the primary trunk line (Channel A), the internal communication handler seamlessly uses the data stream from Channel B within microseconds, eliminating data dropouts or process stops.
Q2: Why is the 640 mA Flexbus output current threshold important when constructing an I/O rack?
A2: The 640 mA rating dictates the maximum logic current the adapter can feed to connected expansion modules down the backplane. Sum up the internal bus current requirements of all attached analog or discrete cards to ensure their total draw does not exceed this 640 mA maximum threshold.
Q3: What advantage do the 60 dB noise and 100 dB common mode rejection ratings provide in production fields?
A3: Heavy industrial machinery, such as large variable frequency drives (VFDs) and high-power welding apparatus, can generate severe electromagnetic field fluctuations. These specific rejection levels shield your real-time input telemetry data from corruption, ensuring it transfers back to the central controller with an accuracy profile of ±0.1%.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Nima uchun PLC signal aralashuvi 61% to‘xtatishlarga sabab bo‘ladi?
Og‘ir yuk liniyalari EMI va yuk zarbalari tufayli yig‘ish liniyalariga nisbatan 3,2 barobar ko‘proq boshqaruv xatolar...
-
Bulut Avtomatizatsiyasining Tasdiqlangan ROIsi Nima?
Global ishlab chiqaruvchilar tarqalgan joylar va cheklangan texnik xizmat ko‘rsatish xodimlariga duch kelishadi. Ushb...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...
