Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1794-OB16P
Allen-Bradley 1794-OB16P Electronic Fused Output 24VDC
Manufacturer: Allen-Bradley
Product No.: 1794-OB16P
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 78g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 1794-OB16P Flex I/O DC Fused Output Module
Allen-Bradley 1794-OB16P | Flex I/O discrete DC output module with 16 electronically fused sourcing output channels. Operates at 24V DC nominal voltage with 8.0 A total output current rating. Each channel provides electronic fusing for protection against overload conditions. Weight: approximately 78 g (2.75 oz).
Key Features
16 current sourcing outputs with electronic fusing. 24V DC nominal on-state voltage (10-31.2V DC range). 8.0 A total output current rating (500 mA per channel, 1 mA minimum). Maximum on-state voltage drop 0.5V DC. Maximum off-state leakage 0.5 mA. 50V continuous isolation voltage. Surge current 2 A for 50 ms, repeatable every 2 seconds. Output signal delay 0.5 ms (OFF-to-ON) and 1 ms (ON-to-OFF). 60 mA Flexbus current at 5V DC. 16 yellow status indicators. DIN rail mounting.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OB16P |
| Product Type | Flex I/O Digital DC Output Module |
| Outputs | 16 (Sourcing, electronically fused) |
| On-State Voltage (Nominal) | 24V DC |
| On-State Voltage (Min) | 10V DC |
| On-State Voltage (Max) | 31.2V DC |
| Output Current Rating | 8.0 A (total) |
| On-State Current (Min) | 1 mA per channel |
| On-State Current (Max) | 500 mA per channel |
| On-State Voltage Drop | 0.5V DC max |
| Off-State Leakage Current | 0.5 mA max |
| Isolation Voltage | 50V continuous |
| Surge Current | 2 A for 50 ms, repeatable every 2 s |
| Signal Delay (OFF-to-ON) | 0.5 ms |
| Signal Delay (ON-to-OFF) | 1 ms |
| Flexbus Current | 60 mA @ 5V DC |
| Power Dissipation | 5.0 W @ 31.2V DC |
| Thermal Dissipation | 17.0 BTU/hr @ 31.2V DC |
| External Power Supply | 10-31.2V DC, 5% AC ripple, 25-75 mA |
| Indicators | 16 Yellow status indicators |
| Mounting | DIN Rail |
| Wire Size | Determined by installed terminal base |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Storage Temperature | -40°C to +85°C (-40°F to 185°F) |
| Relative Humidity | 5-95% non-condensing |
| Vibration | 5g @ 10-500 Hz |
| Operating Shock | 30 g |
| Weight | Approx. 78 g (2.75 oz) |
| UPC | 10612598179968 |
Compatible Terminal Base Units
1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK, 1794-TBN, 1794-TBNK, 1794-TBKD.
Installation Notes
Install on compatible terminal base with DIN rail attachment. Use screw clamp terminations for field wiring. Connect external DC supply of 10-31.2V DC with 5% AC ripple and 25-75 mA current. Compatible with ControlNet, DeviceNet, PROFIBUS, and EtherNet/IP communication adapters. Functions as distributed I/O for ControlLogix, CompactLogix, PLC5, and SLC500 controllers. Operate within 0°C to 55°C ambient temperature.
Engineering Advantages
Electronic fusing on each channel eliminates the need for replaceable fuses and simplifies maintenance. 16 sourcing outputs maximize channel density in a single module. High 8.0 A module rating handles demanding DC loads directly. Fast 0.5 ms OFF-to-ON response supports time-critical control applications. Wide 10-31.2V DC range accommodates supply variations. Compatible with multiple communication adapters and legacy controllers for flexible system integration.
FAQs
Q1: How many outputs does this module provide?
A1: 16 electronically fused sourcing DC outputs, 500 mA per channel.
Q2: What protection does each channel have?
A2: Each channel is electronically fused for overload protection.
Q3: What communication adapters are compatible?
A3: ControlNet, DeviceNet, PROFIBUS, and EtherNet/IP.
Qo'shimcha Texnik Tavsiflar
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...