Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1794-OA8
Allen-Bradley 1794-OA8 Flex I/O AC Output Module
Manufacturer: Allen-Bradley
Product No.: 1794-OA8
Product Type: AC Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 1794-OA8 Flex I/O AC Digital Output Module
Allen-Bradley 1794-OA8 | Flex I/O AC digital output module with 8 non-isolated output channels. Operates at 120V AC nominal voltage with 4.0 A output current rating. Designed for all non-hazardous industrial environments and Class 1, Division 2 areas. Weight: approximately 0.15 kg (0.33 lbs).
Key Features
8 non-isolated outputs in one group. 120V AC nominal output voltage, 85-132V AC range. 4.0 A output current rating. Minimum on-state current 5 mA per output. Maximum on-state voltage drop 1.0V at 0.5 A. Maximum off-state leakage 2.25 mA. 120V continuous isolation voltage. 80 mA Flexbus current at 5V DC. Surge current 7 A for 40 ms, repeatable every 8 seconds. Output signal delay max 1/2 cycle. Diagnostics for field devices, wiring, and power supply. Lightweight at 0.15 kg (0.33 lbs).
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OA8 |
| Product Type | Flex I/O Digital Output Module |
| Outputs | 8 (Non-isolated) |
| Output Voltage (Nominal) | 120V AC |
| Output Voltage Range | 85-132V AC |
| Output Current Rating | 4.0 A |
| On-State Current (Min) | 5 mA per output |
| On-State Voltage Drop | 1.0V max @ 0.5 A |
| Off-State Leakage Current | 2.25 mA max |
| Isolation Voltage | 120V continuous |
| Flexbus Current | 80 mA @ 5V DC |
| Surge Current | 7 A for 40 ms, repeatable every 8 s |
| Signal Delay (ON/OFF) | Max 1/2 cycle |
| Power Dissipation | 4.1 W @ 0.5 A; 6.3 W @ 0.75 A and 1 A |
| Thermal Dissipation | 14.0 BTU/hr @ 0.5 A; 21.2 BTU/hr @ 0.75 A; 21.4 BTU/hr @ 1 A |
| Weight | Approx. 0.15 kg (0.33 lbs) |
| UPC | 10612598137845 |
Current Derating by Temperature
| 55°C | 500 mA per output |
| 35°C | 750 mA per output |
| 30°C | 500 mA on 4 outputs; 1 A on 4 non-adjacent outputs |
Compatible Terminal Base Units
1794-TBNK, 1794-TBKD, 1794-TB3K, 1794-TBNFK, 1794-TB3SK, 1794-TBNF, 1794-TB3, 1794-TB2, 1794-TB3S, and 1794-TBN. Auxiliary terminal strips are required when using the 1794-TBN base unit.
Installation Notes
Install directly on compatible Flex I/O terminal base units. Use auxiliary terminal strips when mounting on the 1794-TBN base. Observe current derating based on ambient temperature: 500 mA per output at 55°C, 750 mA at 35°C. Verify off-state leakage does not affect connected loads. Ensure proper grounding per Allen-Bradley wiring guidelines. Suitable for non-hazardous and Class 1 Division 2 environments.
Engineering Advantages
Integrated diagnostics identify faults in field devices, wiring, and power supply, reducing commissioning and troubleshooting time. 8 outputs in a single Flex I/O module maximize channel density. High 4.0 A module rating handles demanding AC loads directly. Surge current capability of 7 A supports inductive load switching. Wide 85-132V AC range accommodates supply variations. Modular Flex I/O design enables flexible system expansion.
FAQs
Q1: How many outputs does this module provide?
A1: 8 non-isolated AC outputs in a single group.
Q2: What is the output voltage range?
A2: 85-132V AC, with a nominal rating of 120V AC.
Q3: What is the current rating at different temperatures?
A3: 500 mA per output at 55°C, 750 mA per output at 35°C, and 1 A on 4 non-adjacent outputs at 30°C.
Qo'shimcha Texnik Tavsiflar
- Kulrang
- Oq
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...