Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1783-US8T
Allen-Bradley 1783-US8T Stratix 2000 Unmanaged Switch
Manufacturer: Allen-Bradley
Product No.: 1783-US8T
Product Type: Ethernet Switch
Product Origin: USA
Payment:T/T, Western Union
Weight: 380g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Allen-Bradley 1783-US8T is a reliable Stratix 2000™ unmanaged Ethernet switch designed for simple, plug-and-play connectivity in industrial automation environments. Featuring eight (8) RJ45 Fast Ethernet ports, this switch provides an easy way to expand your network without the need for complex configuration. Its compact, open-style design is optimized for DIN rail mounting within control panels, offering a cost-effective solution for connecting controllers, HMIs, and other Ethernet-enabled field devices.
Technical Configuration
- Manufacturer: Rockwell Automation / Allen-Bradley
- Model Series: Stratix 2000
- Catalog Number: 1783-US8T
- Port Count: 8 RJ45 Copper Ports (10/100 Mbps)
- Power Input: 24V Nominal (Supports 12-48V DC or 18-30V AC)
- Switch Type: Unmanaged (Plug-and-Play)
- Mounting: DIN Rail Mount (Open-style rating)
Technical Specifications
| Net Weight | 0.38 kg (0.84 lbs) | Operating Temp | 0 to 60°C (32 to 140°F) |
| Dimensions (HxWxD) | 114.5 x 45.6 x 76.8 mm | Inrush Current | 1.31 A (Maximum) |
| Power Consumption | 4.6 W; Wiring Category 1 (Power) & Category 2 (Communication) | ||
Installation & Powering Features
1. Versatile Power Options: The 1783-US8T is highly flexible regarding power sources. It accepts a wide range of DC voltages (12-48V) and can also be powered by 24V AC, making it compatible with various machine power distribution standards. To ensure safety, the power input must be supplied by a SELV (Safety Extra Low Voltage) source.
2. Grounding Requirements: For reliable operation and noise immunity, the switch requires a functional earth connection. It is recommended to use 2.5 mm² (14 AWG) copper wire with a suitable ring terminal for the grounding lug, ensuring the wire is rated for at least 30°C above the surrounding ambient temperature.
3. Space-Saving Design: With a narrow width of approximately 45.6 mm, the 1783-US8T is designed to fit into crowded control cabinets. The "open-style" rating means the switch should be installed in an appropriate industrial enclosure (such as a NEMA or IP rated cabinet) to protect the internal components from environmental contaminants.
Engineering Advantages
The Stratix 2000 series removes the technical barrier to industrial networking. The 1783-US8T automatically negotiates speed and duplex settings for each connected device, eliminating the need for IT intervention or software management. With a maximum power consumption of only 4.6W and robust vibration/shock resistance, this switch is engineered for long-term stability in factory floor environments where reliability is paramount for non-stop production cycles.
Technical FAQs
Q1: Does this switch support Gigabit speeds?
A1: No, the 1783-US8T features Fast Ethernet ports with speeds up to 100 Mbps, which is sufficient for the majority of industrial I/O and PLC communication tasks.
Q2: Can I use fiber optic connections with this model?
A2: This specific model (1783-US8T) features 8 RJ45 copper ports only. For fiber optic capability, you would need a Stratix 2000 model that includes SFP ports.
Q3: Is any configuration software required for startup?
A3: No. As an unmanaged switch, the 1783-US8T works immediately upon power-up and connection to the network.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
