Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1762-OX6I
Allen-Bradley 1762-OX6I MicroLogix Isolated Relay Module
Manufacturer: Allen-Bradley
Product No.: 1762-OX6I
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 220g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 1762-OX6I MicroLogix Isolated Relay Output Module
Allen-Bradley 1762-OX6I | MicroLogix 1200 series isolated relay output expansion module with 6 individually isolated Form C contact outputs. Compatible with MicroLogix 1100, 1200, and 1400 controllers. Each output provides one Normally Open and one Normally Closed terminal for flexible switching. DIN rail or panel mounting. Weight: approximately 220 g (0.485 pounds).
Key Features
6 individually isolated Form C relay outputs. Operating voltage range 5-125VDC and 5-265VAC. 7 A continuous current per point. 10 ms maximum ON signal delay, 20 ms maximum OFF delay. 110 mA bus current draw at 5VDC and 24VDC. 6 isolated groups (outputs 0-5). Flat ribbon cable with female bus connector. Power supply distance rating 6. Requires 2-inch clearance on all sides for airflow. Compatible with MicroLogix 1100/1200/1400.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1762-OX6I |
| Product Family | MicroLogix 1200 |
| Product Type | Discrete Output Module |
| No. of Outputs | 6 (Isolated Relay) |
| No. of Groups | 6 (individually isolated) |
| Output Form | Type C Relay (1 N.O. + 1 N.C.) |
| Output Voltage Range | 5-125V DC; 120/240V AC |
| Operating Voltage Range | 5-264V AC; 5-125V DC |
| Voltage Category | AC/DC Type |
| Continuous Current per Point | 7 A |
| Signal Delay (ON) | 10 ms max (6 ms typical) |
| Signal Delay (OFF) | 20 ms max (12 ms typical) |
| Bus Current Draw | 110 mA @ 5V DC; 110 mA @ 24V DC |
| Power Supply Distance Rating | 6 |
| Compatible Controllers | MicroLogix 1100 / 1200 / 1400 |
| Mounting Type | DIN Rail or Panel Mount |
| Connection | Flat ribbon cable with female bus connector |
| Dimensions (H x W x D) | 90 x 40.4 x 87 mm (3.54 x 1.59 x 3.43 in) |
| Weight | Approx. 220 g (0.485 lbs) |
| Operating Temperature | 0°C to +55°C (32°F to 131°F) |
| Maximum Altitude | 2000 m (6561 ft) |
Installation Notes
Leave 2-inch (50.8 mm) clearance on all sides of the module for proper airflow and to prevent overheating. Mount on DIN rail with end anchors, or use two Panhead screws per module for high-vibration environments. Connect to the controller and adjacent I/O modules using a flat ribbon cable with female bus connector. Up to 4 modules can be used with MicroLogix 1100, 6 with MicroLogix 1200, and 7 with MicroLogix 1400.
Engineering Advantages
Individually isolated Form C relays allow each channel to switch independent circuits, simplifying mixed-voltage installations. High 7 A per point rating handles demanding loads directly without interposing relays. Form C contacts provide both normally open and normally closed options on every channel. Dual AC/DC voltage capability eliminates the need for separate output module types. Compact 220 g design with flexible mounting options simplifies panel layout.
FAQs
Q1: How many outputs does this module provide?
A1: 6 individually isolated Form C relay outputs.
Q2: What is the maximum current per point?
A2: 7 A continuous current per point.
Q3: How many modules can be connected to each controller?
A3: Up to 4 with MicroLogix 1100, 6 with MicroLogix 1200, and 7 with MicroLogix 1400.
Qo'shimcha Texnik Tavsiflar
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...