Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1756-OW16IK
Allen-Bradley 1756-OW16IK | Isolated Relay Output 16-Point
Manufacturer: Allen-Bradley
Product No.: 1756-OW16IK
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 414g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Allen-Bradley 1756-OW16IK is a conformally-coated Isolated Relay Output Module for ControlLogix 5580 controllers. It provides 16 normally open, individually isolated outputs rated for 10-265V AC and 5-150V DC operation. The module weighs 0.414 kg and fits a single rack slot for flexible system integration.
Core Functionality
The 1756-OW16IK drives pilot duty loads such as relays, contactors, and solenoids with C300/R150 pilot duty rating. Each of the 16 outputs is individually isolated, preventing cross-channel faults. Maximum output delay time is 10ms for responsive switching. The module communicates with Logix5000 controllers via rack-optimized or direct connections, supporting both local and remote chassis installation over EtherNet, ControlNet, or IP networks.
Technical Specifications
| Parameter | Value |
| Part Number | 1756-OW16IK |
| Series | ControlLogix |
| Module Type | Isolated Relay Output Module |
| Outputs | 16 (individually isolated, N.O.) |
| Operating Voltage | 10-265V AC / 5-150V DC |
| Output Current | 2A / 0.5A / 0.25A (load dependent) |
| Max Output Delay | 10 ms |
| Min Load Current per Point | 10 mA |
| Pilot Duty Rating | C300 / R150 |
| Backplane Current (5V / 24V) | 150 mA / 150 mA |
| Power Dissipation (Max) | 4.5W at 60°C |
| Thermal Dissipation | 15.35 BTU/hr |
| Isolation Voltage | 250V continuous |
| Initial Contact Resistance | 100 mΩ at 6V, 1A |
| Expected Contact Life | 300k resistive / 100k inductive |
| Terminal Blocks | 1756-TBCH / 1756-TBS6H |
| Operating Temperature | 0°C to 60°C |
| Weight | 0.414 kg (0.91 lbs) |
Installation Guide
Insert the 1756-OW16IK into any single ControlLogix chassis slot. Power down the chassis before insertion to avoid arc hazards in hazardous locations. Connect field wiring using 1756-TBCH or 1756-TBS6H removable terminal blocks, or a Bulletin 1492 IFM. Observe load-dependent current limits per channel. Verify output status via onboard indicators after configuration.
Engineering Advantages
This module delivers 16 individually isolated outputs, preventing a single field fault from affecting other channels. Conformal coating protects against moisture, dust, and corrosive contaminants. The 250V continuous isolation rating ensures safe separation from the backplane. Expected contact life of 300k resistive operations supports long service intervals. Real-time diagnostics via onboard indicators simplify troubleshooting.
Technical FAQs
Q1: What output configuration and voltage range does this module provide?
A1: 16 normally open individually isolated outputs. 10-265V AC and 5-150V DC operating range.
Q2: What is the load-dependent current rating?
A2: 2A, 0.5A, or 0.25A depending on voltage. Minimum load current 10mA per point. C300/R150 pilot duty.
Q3: Which terminal blocks are compatible?
A3: 1756-TBCH and 1756-TBS6H removable terminal blocks, or a Bulletin 1492 IFM.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
