Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1756-IR6I
Allen-Bradley 1756-IR6I ControlLogix 6-Point Isolated RTD Input Module
Manufacturer: Allen-Bradley
Product No.: 1756-IR6I
Product Type: Analog RTD Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 1756-IR6I ControlLogix RTD Input Module
The Allen-Bradley 1756-IR6I is a high-precision, temperature-measuring analog input module for the ControlLogix platform. Featuring six individually isolated channels and a 16-bit resolution architecture, this lightweight 0.32 kg module interfaces with 3-wire and 4-wire RTD sensors to deliver accurate thermal tracking in demanding process environments.
Key Advantages
- Channel-to-Channel Isolation: Six fully independent isolated sensor circuits eliminate ground loop risks and prevent cross-channel signal corruption.
- Dual Processing Modes: Supports baseline integer conversion as well as advanced 32-bit floating-point execution with temperature linearization and process/rate alarming.
- Intelligent Diagnostics: Embedded with under-range/over-range detection, programmable digital notch filters, and real-time wire-off loop sensing.
Technical Specifications
| Input Points | 6 Individually Isolated Channels (20-pin faceplate) |
| Supported RTD Types | Platinum (100, 200, 500, 1000 Ω; α=385/3916), Nickel (100, 120, 200, 500 Ω; α=672/618), Copper (10 Ω) |
| Analog Resolution | 16 bits (7.7 mΩ/bit at 487 Ω max, 15 mΩ/bit at 1000 Ω max, 30 mΩ/bit at 2000 Ω max, 60 mΩ/bit at 4020 Ω max) |
| Module Scan Speeds | 10 ms min (Integer Mode) / 25 ms min (Floating Point Ohms) / 50 ms min (Floating Point Temp) |
| Backplane Current Draw | 250 mA at 5.1 VDC / 125 mA at 24 VDC (Total Power Dissipation: 4.3 Watts max) |
| Operating Scope & Weight | 0°C to 60°C (32°F to 140°F) / Net Module Weight: Approx. 0.32 kg |
Quick Installation
- Chassis Placement: Align and firmly slide the module into any available local or remote I/O slot within the ControlLogix chassis.
- Terminal Block Setup: Wire the sensors using a compatible 1756-TBNH or 1756-TBSH 20-pin Removable Terminal Block (RTB).
- Multicast Configuration: Establish the proper Requested Packet Interval (RPI) and Real-Time Sampling (RTS) parameters to enable deterministic data multicasting.
Technical FAQs
Q1: What are the differences between Integer and Floating-Point data formats?
A1: Integer mode limits scaling data but processes raw readings much faster. Floating-Point mode utilizes the full internal processing library to support temperature linearization, rate alarms, and engineering unit scaling.
Q2: How does the module handle inherent line noise or minor resistance variances?
A2: A built-in digital notch filter minimizes plant electrical field noise, while an integrated 10-ohm copper offset feature compensates for small layout errors on sensitive copper RTD loops.
Q3: How does the wire-off detection feature operate?
A3: The wire-off diagnostic checks loop completeness continuously. If a connection on the terminal block is loosened or a field wire breaks, a system fault flag activates instantly to avoid inaccurate control loops.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...
