Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1756-IM16I
Allen-Bradley 1756-IM16I 16 Channel Isolated AC Input
Manufacturer: Allen-Bradley
Product No.: 1756-IM16I
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Allen-Bradley 1756-IM16I is a premium, heavy-duty 16-point isolated AC digital input module belonging to the high-performance ControlLogix automation platform. Engineered for challenging industrial environments with diverse electrical grids, this module provides complete point-to-point isolation across all 16 channels, operating within a nominal voltage category of 240 Volts AC (159 to 265 VAC range). Weighing approximately 0.30 kg (0.66 lbs), this chassis-based processor card monitors high-voltage field statuses, executes precise Change-of-State (COS) tracking, and protects the core PLC backplane from dangerous multi-phase cross-faults or erratic voltage spikes.
Core Technical Advantages
- Per-Point Individual Isolation: Features 16 completely independent isolated channel grids, permitting the simultaneous monitoring of distinct AC phases or separate field power sources on a single module without phase short-circuit risks.
- Programmable Logic Filter Times: Supports highly customizable input delay filters (selectable up to 18 ms) combined with rapid hardware response times to successfully suppress contact bounce and high-frequency line noise.
- Advanced Thermal Derating Matrix: Optimized to safely dissipate up to 5.8 Watts at 60 degrees Celsius, providing robust multi-channel configuration charts to handle continuous high-temperature field operations with maximum stability.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix System) |
| Model Part Number | 1756-IM16I (UPC 10612598171344) |
| Gross Weight | 0.30 kg (0.66 lbs) |
| Module Category | Isolated Digital AC Input Module |
| Discrete Input Count | 16 Individually Isolated Inputs (Point-to-Point Isolation) |
| Nominal Voltage Category | 240 Volts AC (50 / 60 Hz operating frequency) |
| Continuous Operating Range | 159 to 265 Volts AC (47 to 63 Hz frequency bandwidth) |
| On-State Current Threshold | 5 mA minimum at 159 VAC / 13 mA maximum at 265 VAC |
| Off-State Threshold Limits | Maximum 40 Volts AC / Maximum 2.5 mA leakage current |
| Maximum Inrush Current | 250 mA peak inrush loading capability |
| Backplane Current Requirements | 100 mA at 5 VDC / 3 mA at 24 VDC (Total Bus Power: 0.58 Watts) |
| Thermal / Power Dissipation | 5.8 Watts maximum power loss / 19.78 BTU/hour thermal dissipation |
| Compatible Terminal Housing | 36-Pin Removable Terminal Blocks (1756-TBCH or 1756-TBS6H) |
Installation & Engineering Guide
- Chassis Placement & Insertion: Ensure the primary system power supply is completely isolated before beginning installation. Align the 0.30 kg hardware frame within the selected slot guides of the 1756 ControlLogix chassis, pushing it backward firmly until the top and bottom retention clips snap completely over the structural chassis rail tabs.
- 36-Pin RTB Wiring Configurations: Terminate your 240V AC field inputs through an approved 1756-TBCH (extended clamp) or 1756-TBS6H (spring clamp) 36-pin removable terminal block. Because each channel is fully isolated, always run both the active signal line and its respective neutral return line directly to the designated channel terminal pair.
- Operating Environment Derating: Monitor your local enclosure temperature guidelines closely. When executing full system density, all 16 channels can remain ON up to 30 degrees Celsius at 265 VAC; however, if operating at 40 degrees Celsius, limit simultaneous active channels to 8 points max, or derate the operational input limit down to 242 VAC at 60 degrees Celsius with all channels active.
Technical FAQs
Q1: How is the total execution delay calculated for the 1756-IM16I AC input paths?
A1: The total turnaround delay from screw to backplane is a combination of native hardware circuit latency and user-selected filter times. Going from Off-to-On, it equals the 10 ms max hardware delay plus a selectable 1 or 2 ms filter. Going from On-to-Off, it is an 8 ms max hardware delay plus a selectable 9 or 18 ms filter block.
Q2: What is the main advantage of point-to-point isolation on this specific digital input card?
A2: Unlike standard grouped inputs that share a common return bus, per-point isolation provides a completely separate circuit for each of the 16 paths. This allows you to mix different AC voltage phases or feed signals from entirely separate safety substations into a single physical card without risk of catastrophic cross-phase failure.
Q3: Does the lightweight 0.30 kg construction of this module compromise its long-term reliability?
A3: No. At roughly 0.30 kg, its specialized compact frame is optimized to save chassis balance while providing rugged structural components that comply with high-voltage industrial insulation profiles, fully meeting standard ControlLogix ratings for mechanical shock and vibrations.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why Driver Version Matching Matters for FactoryTalk Setup?
This guide provides standardized workflows for integrating Emerson DeltaV, ABB AC800, and GE Fanuc 90 with FactoryTal...
-
Can You Trust Your ABB and Bently Nevada MRO Supplier?
This article presents five data-backed standards for selecting an industrial automation parts supplier for ABB, Allen...
-
Can VersaMax PLC Expansion Fix Auto I/O Bottlenecks?
This article examines GE Fanuc VersaMax PLC expansion for automotive assembly I/O constraints. A 12-station SUV plant...
-
Is Your Legacy DCS Costing You 35% More Downtime Each Year?
This technical article presents a data-driven strategy for migrating end-of-life Emerson DCS to ABB 800F systems with...
-
What Is the Real Hourly Cost of Automation Downtime?
Industrial automation downtime creates severe financial losses, with PLC and DCS hardware failures causing 62% of unp...
-
Does Bently Nevada & PLC Integration Cut Refinery Downtime?
This article details a field-validated Bently Nevada 3500 and Allen-Bradley ControlLogix integration for oil and gas ...
