Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1734-IT2I
Allen-Bradley 1734-IT2I | POINT I/O Isolated TC Module
Manufacturer: Allen-Bradley
Product No.: 1734-IT2I
Product Type: Input RTD Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 36g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Allen-Bradley 1734-IT2I is a POINT I/O isolated analog temperature input module with 2 differential, individually isolated thermocouple inputs. It delivers 15-bit resolution at 2.5 µV/count with a ±75 mV input voltage range. Weighing 0.08 pounds (0.036 kg), this open-style module requires no external DC power supply but installs only on the 1734-TBCJC wiring base assembly.
Technical Configuration
This module produces 8 bytes of scanner data (scanner Rx) and fault status data without consuming I/O data (scanner Tx). It supports signed integer data format with 4 temperature scales (Celsius, Fahrenheit, Kelvin, Rankine) plus 1 mV custom scale. Delta Sigma conversion ensures stable readings. Status indicators monitor network state, module state, input 0 state, and input 1 state in real time. The key switch position is 6.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IT2I |
| Series | POINT I/O |
| Module Type | Analog Temperature Input Module |
| Inputs | 2 differential, individually isolated thermocouple |
| Resolution | 15 bits at 2.5 µV/cnt |
| Input Voltage | ±75 mV |
| Voltage Rating | 24V DC |
| POINTBus Current | 175 mA at 5V DC |
| Impedance / Resistance | 100 kΩ / 1 MΩ |
| Conversion Type | Delta Sigma |
| Data Format | Signed integer |
| Temperature Scales | Celsius, Fahrenheit, Kelvin, Rankine, plus 1 mV custom scale |
| Alarms | Under-range, over-range, CJC open-wire, level (low-low, low, high, high-high) |
| Power Dissipation | Max 1 Watt |
| Thermal Dissipation | Max 3.3 BTU/hour |
| Isolation Voltage | 50V continuous |
| Keyswitch Position | 6 |
| Wiring Base | 1734-TBCJC only |
| Dimensions (H x W x D) | 2.21 x 0.47 x 2.97 in |
| Weight | 0.08 lbs (0.036 kg) |
| Operating Temperature | -20 to 55°C |
| Storage Temperature | -4 to 85°C |
| Operating Vibration | 5 g at 10-500 Hz |
| Enclosure | Open style |
Installation Guide
Rotate the keyswitch to position 6 before installing the module. Mount only on the 1734-TBCJC wiring base assembly, which provides cold junction compensation. Wire thermocouple leads observing proper polarity for differential inputs. No external DC power supply is required. Configure the desired temperature scale (Celsius, Fahrenheit, Kelvin, Rankine) or mV custom scale, then enable alarm thresholds for under-range, over-range, and CJC open-wire detection.
Engineering Advantages
This module provides individually isolated differential thermocouple inputs, preventing ground loop interference between separate sensors. The 15-bit resolution at 2.5 µV/count enables detection of small temperature changes. CJC open-wire detection alerts operators to broken thermocouple circuits before process disruption. Four level alarms (low-low, low, high, high-high) support multi-stage process protection. The 8-byte scanner data output operates independently of I/O data consumption, simplifying configuration.
Technical FAQs
Q1: What type of inputs does the 1734-IT2I provide?
A1: This module provides 2 differential, individually isolated thermocouple inputs with ±75 mV range and 15-bit resolution at 2.5 µV/count.
Q2: What wiring base is required for this module?
A2: The 1734-IT2I installs only on the 1734-TBCJC wiring base assembly, which provides cold junction compensation.
Q3: What alarms does this module support?
A3: It provides under-range, over-range, CJC open-wire detection, and four level alarms (low-low, low, high, high-high).
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...