Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:ACS510-01-04A1-4
ABB ACS510-01-04A1-4 VFD | 2.2kW Inverter Drive
Manufacturer: ABB
Product No.: ACS510-01-04A1-4
Product Type: Inverter Drive
Product Origin: SE
Payment:T/T, Western Union
Weight: 8200g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
ABB ACS510-01-04A1-4 Drive Overview
The ABB ACS510-01-04A1-4 is an energy-efficient industrial variable frequency drive (VFD) optimized for fan and pump applications. It provides a reliable 2.2 kW power output and a 5.6 A normal use current under a 3-phase 380-480V supply. Featuring an R1 frame size, an IE2 efficiency rating, and a space-saving wall-mounted layout, this module ensures smooth motor operation and low operational overhead.
Core Technical Advantages
Advanced V/F Control
Optimized scalar control mechanics accurately regulate motor speed for linear and quadratic torque loads, optimizing power use for industrial fans and centrifugal pumps.
High Efficiency & Low Losses
Boasts a certified IE2 efficiency rating with a low 11 W standby power loss, drastically lowering long-term system energy costs.
Integrated Modbus Network
Built-in RS485 communication terminal block enables native Modbus protocol networking for straightforward setup, parameter monitoring, and DCS pairing.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Power Capacity / Current | 2.2 kW / 5.6 A (Normal Use) |
| Input / Apparent Power | 380 V to 480 V (3-Phase) / 3.5 kVA |
| Supply / Output Frequency | 50 to 60 Hz (Tolerance: 47.5 to 63 Hz) |
| Efficiency / Standby Loss | IE2 Rating / 11 W |
| Enclosure Class / Frame | IP21 (NEMA Type 1) / Frame Size R1 |
| Cooling Method | Integrated Fan Cooling |
| Dimensions & Weight | 40 x 24 x 48.5 cm / 8.2 Kg |
Installation & Engineering Guide
Mounting & Thermal Management
Secure the 8.2 Kg R1 frame housing vertically onto a rigid, non-flammable wall surface. Ensure clear air channels around the unit so the internal fan cooling system disperses heat properly.
Wiring Connections
Make all power and control runs through the marked terminal block channels. Adhere strictly to the 3-phase 380-480V limits to prevent internal drive hardware failures.
Environmental Limitations
Operates continuously within an ambient temperature spectrum of -10°C to +50°C. Protect the IP21/NEMA Type 1 enclosure from direct water leaks and highly humid rooms.
Technical FAQs
Q1: What types of systems are best suited for this drive's control method?
A1: The V/F control profile is custom-engineered for variable torque industrial setups, such as commercial pumps and multi-speed ventilation fans.
Q2: Can this drive be mounted horizontally inside low-profile cabinets?
A2: No. This unit is designed solely for vertical wall-mounted installation to allow the cooling fan to maintain standard thermal metrics.
Q3: Does the drive include built-in communication ports for automation?
A3: Yes. It includes a terminal block interface running RS485 serial communication, completely compatible with standard Modbus RTU plant loops.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
-
How Do Bently Nevada Transmitters Improve Bearing Health Monitoring?
This technical article examines the role of Bently Nevada vibration transmitters in industrial automation for ea...
-
What Are the Real ROI Gains of Upgrading Legacy Turbine Monitoring?
Operating legacy turbine supervisory instrumentation (TSI) beyond 12 years exposes power stations to false trips, pro...
