Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:6ES7313-1AD03-0AB0
6ES7313-1AD03-0AB0 Siemens S7-300 CPU 313 Original Stock
Manufacturer: Siemens
Product No.: 6ES7313-1AD03-0AB0
Product Type: CPU Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 530g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
SIEMENS 6ES7313-1AD03-0AB0 SIMATIC S7-300 CPU 313
The SIEMENS 6ES7313-1AD03-0AB0, also cataloged as the 6ES7313-1AD03-0AB0 CPU 313, operates as a central processing unit with integrated 24 VDC power supply executing user logic within SIMATIC S7-300 platforms at 12 kbyte working memory.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7313-1AD03-0AB0 |
| Brand | Siemens |
| Product Type | CPU 313 Spare Part |
| Series | SIMATIC S7-300 |
| Rated Supply Voltage | 24 VDC |
| Permissible Range | 20.4 V to 28.8 VDC |
| Inrush Current | 8 A typ. |
| Power Loss | 8 W typ. |
| Work Memory | 12 kbyte integrated (12 KB / 4K instructions RAM) |
| Load Memory | FEPROM expandable to 4 Mbyte, integrated RAM 20 kbyte max |
| Backup | Battery (all blocks) or battery-free (72 bytes) |
| Bit Operation Time | 0.6 us typ., 1.2 us max |
| Word Operation Time | 2 us typ. |
| Fixed Point Arithmetic | 3 us typ. |
| Floating Point Arithmetic | 60 us typ. |
| Timer/Counter Operation | 15 us typ. |
| S7 Counters | 64 (35 retentive with or without battery) |
| S7 Timers | 128 (35 retentive with battery) |
| Flag Memory | 256 byte max (M 0.0 to M 71.7 retentive) |
| Digital Channels | 256 inputs, 256 outputs |
| Analog Channels | 64 inputs, 32 outputs |
| MPI Interface | 1 x MPI, max 32 nodes, 187.5 kbit/s max |
| Dimensions (W x H x D) | 80 mm x 125 mm x 130 mm |
| Weight | 530 g (approx.), memory card 16 g |
CPU Function and MPI Communication
Unit weight is approximately 530 g with dimensions of 80 mm width, 125 mm height, and 130 mm depth. The CPU 313 integrates a 24 VDC power supply and 12 kbyte working memory supporting 4K instructions. Load memory is expandable via Flash-EPROM to a maximum of 4 Mbyte, with 20 kbyte integrated RAM. Battery-backed backup retains all blocks; battery-free backup retains 72 bytes of memory bits, times, counters, and data. The integrated MPI interface supports up to 32 nodes at a maximum transmission rate of 187.5 kbit/s. Without repeaters, MPI cable length is limited to 50 m; with 2 repeaters, 1100 m; with 10 repeaters in series, 9100 m; via fiber optic cable, 23.8 km with 16 star hubs or OLMs. Per CPU, a maximum of 4 static and 4 dynamic connections are supported. Programming uses STEP 7 V5.0 or higher. Cycle time monitoring is adjustable from 1 ms to 6000 ms with a preset of 150 ms. SCL is supported as an optional programming language. User program protection via password is available.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7313-1AD03-0AB0?
A: Approximately 530 g, with dimensions of 80 mm width, 125 mm height, and 130 mm depth. The memory card weighs approximately 16 g.
Q: What is the maximum MPI cable length supported by the CPU 313?
A: 50 m without repeaters, 1100 m with 2 repeaters, 9100 m with 10 repeaters in series, and 23.8 km via fiber optic cable with 16 star hubs or OLMs.
Q: What programming software is required for this CPU?
A: STEP 7 V5.0 or higher. SCL is supported as an optional programming language.
Field Installation Guidelines
Install the CPU in slot 2 of the S7-300 rail and secure the mounting screws. Verify 24 VDC supply polarity before energizing the backplane. Confirm STEP 7 V5.0 or higher is used for configuration. Route MPI cable within the calculated repeater limits for the required distance. Verify battery backup is installed if all blocks must be retained after power loss; otherwise only 72 bytes are retained without battery. Configure cycle time monitoring between 1 ms and 6000 ms based on the application scan time. Verify module bus connections to adjacent I/O modules after insertion.
Qo'shimcha Texnik Tavsiflar
- DC quvvatlanadigan
- Modulli
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
