Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:25B-E012N104
25B-E012N104 Allen-Bradley PowerFlex 525 Drive 12A 10HP
Manufacturer: Allen-Bradley
Product No.: 25B-E012N104
Product Type: AC Drive
Product Origin: USA
Payment:T/T, Western Union
Weight: 2300g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 25B-E012N104 PowerFlex 525 AC Drive
Product Overview
The Allen-Bradley 25B-E012N104 is a PowerFlex 525 series variable frequency drive delivering 12.0 A output current with 7.5 kW (10.0 HP) power rating. It operates on 3-phase 446-660 VAC input (nominal 525-600 VAC) and provides 0-575 VAC output. The drive achieves 97.5% efficiency and supports V/Hz, Sensorless Vector, and Closed Loop Vector control methods. Weight is 2.3 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 25B-E012N104 |
| Series | PowerFlex 525 |
| Input Voltage Range | 446-660 VAC (Nominal 525-600 VAC), 3-Phase |
| Input Frequency | 47-63 Hz |
| Output Voltage | 0-575 VAC, 3-Phase |
| Output Current | 12.0 A |
| Output Power | 7.5 kW (10.0 HP) |
| Output Frequency | 0-500 Hz (programmable) |
| Efficiency | 97.5% |
| EMC Filtering | Not included (optional) |
| Control Methods | V/Hz, Sensorless Vector, Closed Loop Vector |
| PWM Control | Sinusoidal PWM output |
| Discrete Inputs | 7 Sink/Source |
| Discrete Outputs | 2 Digital/Optocoupler |
| Relay Outputs | 1 N.O., 1 N.C. |
| Analog Inputs | 2 (0-10 VDC / 0-20 mA) |
| Analog Output | 1 (0-10 VDC / 0-20 mA) |
| Communication | RS-485, EtherNet/IP |
| Stop Modes | Ramp, Coast, DC Brake, Ramp-to-Stop |
| Accel/Decel Profiles | 4 programmable (0.01s to 600s) |
| Weight | 2.3 kg |
Key Features
- 12.0 A output current with 7.5 kW (10.0 HP) power rating
- 3-phase 446-660 VAC input voltage range
- 97.5% efficiency for reduced energy costs
- Supports V/Hz, Sensorless Vector, and Closed Loop Vector control
- Compatible with surface/interior permanent magnet and induction motors
- Internal PI controller for standalone control
- Embedded RS-485 and EtherNet/IP communication
- Premier Integration with Logix controllers for remote access
- Seven discrete inputs and two analog inputs for flexible control
- Four programmable accel/decel profiles from 0.01s to 600s
- Multiple stop modes: Ramp, Coast, DC Brake, Ramp-to-Stop
- Local HIM interface for programming, monitoring, and diagnostics
Installation Notes
Mount the drive in a vertical position with adequate clearance for airflow. Ensure proper grounding and cable sizing for 12.0 A output. The drive supports multiple motor types including permanent magnet and induction motors. Configure control method (V/Hz, SVC, or CLV) based on application requirements. For EMC compliance in sensitive environments, add the optional external filter. Use the embedded HIM interface for local programming or connect via EtherNet/IP for remote configuration.
FAQs
Q1: What is the output power rating of the 25B-E012N104?
A1: 7.5 kW (10.0 HP) with 12.0 A output current.
Q2: What communication protocols does this drive support?
A2: Embedded RS-485 and EtherNet/IP, with Premier Integration support for Logix controllers.
Q3: What motor types are compatible with this drive?
A3: Surface/interior permanent magnet motors and induction motors.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
