Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:VFD007EL43A
1HP 480V Delta VFD007EL43A Variable Frequency Drive
Manufacturer: Delta
Product No.: VFD007EL43A
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1200g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The VFD007EL43A is a high-efficiency, micro-type AC motor drive from Delta’s versatile VFD-EL Series. Developed for low-horsepower industrial applications, this 1 HP (0.75 kW) variable frequency drive provides precise speed control for fans, pumps, conveyors, and automated assembly machinery. It operates on a 3-phase 380 to 480 V AC input and delivers a stable 2.5 A output current. Featuring a space-saving Frame A footprint, a lightweight structural design weighing just 1.2 kg (2.65 lbs), and an onboard digital keypad, it integrates seamlessly into high-voltage control architectures without taking up excessive panel space.
Core Technical Advantages
Space-Saving Frame A Design
The highly compact Frame A layout supports side-by-side DIN rail mounting. This optimized physical architecture allows system integrators to maximize internal cabinet space and build dense, multi-drive control panels.
Advanced Dynamic Braking
Equipped with an internal dynamic braking transistor alongside programmable DC Injection braking, the drive handles rapid deceleration cycles safely. It quickly dissipates regenerative energy, ensuring high stopping accuracy for cyclic or high-inertia loads.
High-Speed Spindle Capability
With an adjustable output frequency reaching up to 600 Hz, this scalar V/Hz drive efficiently runs high-speed motors commonly found in commercial woodworking, textile production, and precision machining spindles.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Products (VFD-EL Series) |
| Model Number | VFD007EL43A |
| Motor Power Capacity | 1.0 HP / 0.75 kW |
| Rated Output Current | 2.5 Amps |
| Nominal Input Voltage | 480 Volts AC (Operational Range: 380–480 V) |
| Input Phase Configuration | 3-Phase |
| Net Device Weight | 1.2 kg (2.65 lbs) |
| Enclosure Protection Rating | IP20 |
| Dimensions (H × W × D) | 6.86 × 2.83 × 5.36 Inches |
Installation and Maintenance
Environmental Requirements
The IP20 open-type enclosure requires installation inside a clean, dry control panel. Protect the drive from airborne contaminants, corrosive gases, and moisture. Ensure adequate vertical clearance above and below the Frame A chassis to maintain natural convection or fan-assisted airflow.
Power and Motor Wiring
Connect incoming 3-phase utility power strictly to the main line input terminals (R, S, T). Terminate the motor leads to the output terminals (U, V, W). Never connect AC line power to the output terminals, as backward power injection will instantly damage the internal IGBT modules.
Braking Resistor Implementation
For applications with rapid deceleration steps or high overhauling inertia, wire an external braking resistor across the onboard dynamic braking terminals. This prevents the drive from tripping on overvoltage ($OV$) faults by safely absorbing regenerated energy.
Engineering Advantages
Built-In Operator Interface
The integrated digital keypad provides a clear display interface and digital parameter knob. Operators can modify acceleration ramps, check motor frequency, and diagnose fault codes directly on the unit without needing external computer software.
Cost-Effective Control Profile
By optimizing open-loop V/Hz scalar control, this drive delivers reliable speed regulation, multi-step speeds, and automatic torque compensation without the financial premiums associated with complex vector-capable hardware.
Comprehensive Fault Defense
Embedded electronic protections track overcurrent, overvoltage, thermal overloads, and ground faults continuously. If a limit is breached, the drive trips immediately to shield both the inverter circuit and the connected motor from damage.
Technical FAQs
Q1: Can this 480 V drive be operated using a single-phase AC input supply?
A1: No. This model requires a balanced 3-phase 380–480 V AC input to run safely. Attempting to run it on single-phase power will trigger an input phase loss fault ($PHL$) and prevent the internal DC bus capacitor bank from charging evenly.
Q2: Does this drive support closed-loop encoder monitoring or field-oriented control?
A2: No. The VFD-EL series uses open-loop V/Hz (Scalar) control. If your application demands absolute position feedback, encoder integration, or closed-loop torque control, consider upgrading to the Delta VFD-E or VFD-C2000 series.
Q3: What parameters should be adjusted if the motor stalls during high-torque startup?
A3: If the motor struggles to start under load, try adjusting the manual torque compensation parameter to boost output voltage at low frequencies. Alternatively, increasing the acceleration time ($ACC$) gives the motor more time to overcome initial load inertia.
Qo'shimcha Texnik Tavsiflar
- Qora
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...
