Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1756-EN2T
1756-EN2T Allen-Bradley 10/100 Mbps Ethernet Communication
Manufacturer: Allen-Bradley
Product No.: 1756-EN2T
Product Type: Communication Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 1756-EN2T ControlLogix EtherNet/IP Bridge Module
The module functions as a high-performance communication interface engineered to connect Allen-Bradley ControlLogix controllers to open, industrial EtherNet/IP networks. Occupying a single chassis slot width and weighing approximately 0.35 kg, this versatile bridge adapter acts as a critical link for Industrial Internet of Things (IIoT) architectures, encapsulating standard CIP messages within TCP/IP frameworks to manage up to 128 TCP/IP and 256 Logix connections simultaneously across distributed I/O, HMI, and SCADA systems.
Technical Specifications
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Product Model / Catalog No. | 1756-EN2T |
| System Line Series | ControlLogix Communication System |
| Component Interface Profile | EtherNet/IP Bridge Communication Module |
| Network Transmission Rates | 10 / 100 Mbps Fast Ethernet (Auto-Sensing) |
| Capacity Metrics | 128 TCP/IP connections | 256 Logix connections | Max 8 axes integrated motion |
| Packet Execution Limits | I/O Processing: 10,000 p/s | HMI/MSG Processing: 3,200 p/s |
| Integrated Physical Interfaces | One (1) RJ45 Fast Ethernet Port | One (1) USB 1.1 Configuration Port |
| Backplane Power Usage | 1 A @ 5.1V DC nominal draw (1.2 A maximum continuous boundary) |
| Power & Thermal Dissipation | 5.1 to 6.2 Watts power dissipation | 17.4 to 21.28 BTU/hour heat generation |
| Chassis Space Occupancy | 1-Slot width form factor (Can be placed in any available slot) |
| Insulation Safety Voltage | 30 Volts continuous protection barrier threshold |
| Hardware Net Weight | 0.35 kg / 0.77 lbs robust standalone card weight |
| System Compatibility Matrix | Chassis: 1756-A4, -A7, -A10, -A13, -A17 | Power Supplies: 1756-PA72, -PA75, -PB72, -PB75, -PC75, -PH75 |
Quick Installation Guide
- Verify that the main chassis rack power supply is completely isolated before inserting or extracting interface hardware.
- Align the upper and lower circuit board tracks of the 0.35 kg 1756-EN2T bridge card with any open slot inside the targeted ControlLogix chassis.
- Press the 0.35 kg module firmly into the rack until the structural interlocking top and bottom clips engage with the metal chassis frame.
- Connect a standard Category 5 unshielded twisted-pair (UTP) copper line with an RJ45 connector into the front interface port, configure your local subnet boundaries, and close the terminal shroud.
Technical FAQs
Q1: Why does the 1756-EN2T module require separate tracking for TCP/IP and Logix connection counts?
A1: TCP/IP connections identify the physical network nodes (such as individual computers, HMIs, or third-party hardware controllers) interacting with the bridge. Logix connections represent the internal data paths used by controllers to stream real-time I/O tags, produce/consume data arrays, or communicate messaging parameters concurrently.
Q2: How does a modest 0.35 kg standalone mass cope with heavy communication traffic and thermal loading?
A2: A net mass of 0.35 kg highlights a solid-state layout using optimized communication processing chipsets. While running a full 10,000 p/s I/O packet execution rate, the card dissipates up to 6.2 Watts (21.28 BTU/hour), relying on standard chassis convection pathways within its 0 to 60°C operating window.
Q3: Can this module participate in high-availability, fault-tolerant network topologies?
A3: Yes. The 1756-EN2T bridge includes native firmware support for Device Level Ring (DLR) layouts and Parallel Redundancy Protocol (PRP) structures. This allows the module to withstand an external network cable break without dropping active PLC connections or disrupting industrial process control loops.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why Driver Version Matching Matters for FactoryTalk Setup?
This guide provides standardized workflows for integrating Emerson DeltaV, ABB AC800, and GE Fanuc 90 with FactoryTal...
-
Can You Trust Your ABB and Bently Nevada MRO Supplier?
This article presents five data-backed standards for selecting an industrial automation parts supplier for ABB, Allen...
-
Can VersaMax PLC Expansion Fix Auto I/O Bottlenecks?
This article examines GE Fanuc VersaMax PLC expansion for automotive assembly I/O constraints. A 12-station SUV plant...
-
Is Your Legacy DCS Costing You 35% More Downtime Each Year?
This technical article presents a data-driven strategy for migrating end-of-life Emerson DCS to ABB 800F systems with...
-
What Is the Real Hourly Cost of Automation Downtime?
Industrial automation downtime creates severe financial losses, with PLC and DCS hardware failures causing 62% of unp...
-
Does Bently Nevada & PLC Integration Cut Refinery Downtime?
This article details a field-validated Bently Nevada 3500 and Allen-Bradley ControlLogix integration for oil and gas ...