Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC695ALG112
RX3i IC695ALG112 | GE Fanuc 12 Input Voltage/Current Module
Manufacturer: General Electric
Product No.: IC695ALG112
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 400g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC695ALG112 RX3i 12-Channel Analog Input Module
GE Fanuc IC695ALG112 is a 12-channel analog input module for PACSystem RX3i. It accepts voltage and current signals with 16-bit resolution and configurable digital filtering.
Key Specifications
- Manufacturer: GE Fanuc / Emerson Automation
- Model: IC695ALG112
- Series: RX3i PacSystem
- Type: Analog Input Module
- Channels: 12 single-ended isolated inputs
- Resolution: 16-bit ADC
- Data format: IEEE 32-bit floating point or 16-bit integer
- Input impedance: >500 kΩ (voltage)
- Weight: 0.4 kg
- Power consumption: 4.89W max (all channels at 20mA)
- Thermal derating: None
Input Signal Ranges
- Voltage unipolar: 0 to +10 VDC
- Voltage bipolar: -10 to +10 VDC, ±5 VDC
- Voltage: 0 to 5 VDC, 1 to 5 VDC
- Current: 0-20 mA, 4-20 mA, ±20 mA
Filter Options & Settling Times
- 8 Hz filter: 127 ms settling
- 12 Hz filter: 67 ms settling
- 16 Hz filter: 56 ms settling
- 40 Hz filter: 21 ms settling
- 250 Hz filter: 3.1 ms settling
- 1000 Hz filter: 0 ms settling
- Step change settles to 0.1% within 1.7 ms
Accuracy Specifications
- Calibrated accuracy: 0.1% of range at 25°C
- Full temperature range: 0.2% of range
- RF interference (10V/M): ±2.0% degradation possible
- Calibration interval: 12 months typical
Power Requirements
- Backplane 5V: 600 mA max
- Backplane 3.3V: 800 mA max
Protection Ratings
- Overvoltage: ±35 VDC continuous max
- Overcurrent: ±35 mA continuous max
- Open circuit detection: 1 second maximum
Environmental
- Operating temp: 0°C to 60°C
- Storage temp: -40°C to 85°C
- Humidity: 5-95% non-condensing
FAQs
-
How many channels?
12 single-ended isolated analog inputs. -
What signals are supported?
±10V, 0-10V, ±5V, 0-5V, 1-5V, 0-20mA, 4-20mA, ±20mA. -
What filter options are available?
8Hz, 12Hz, 16Hz, 40Hz, 250Hz, and 1000Hz.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can Modern Automation Reduce Power Plant Downtime?
Discover power plant control system upgrade strategies using PLC & DCS. Real case studies, 24/7 support, and expe...
-
How to Extend DCS and PLC Lifespan With Smart Maintenance?
Effective maintenance of DCS and PLC systems is essential for maximizing uptime and efficiency in industrial automati...
-
Why Combine DCS with Edge Controllers in Oil & Gas?
Expert guide on selecting and maintaining PLC and DCS systems for oil & gas automation. Covers environmental fact...
-
How Does PLC-DCS Integration Boost Power Plant Efficiency?
This article explores strategic approaches to integrating PLC and DCS systems in power plants, featuring real-world c...
-
Are Legacy PLCs Putting Your Petrochemical Operations at Risk?
This article explores the critical role of troubleshooting and optimization in maintaining PLC and DCS reliability wi...
-
What Causes DCS Failures in Power Plants and How to Fix Them?
This article provides a comprehensive guide to managing Distributed Control System (DCS) failures in power generation...