Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693ALG391
IC693ALG391 GE PLC Analog Current Output | 4-20mA 1-Slot Unit
Manufacturer: General Electric
Product No.: IC693ALG391
Product Type: Analog Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC693ALG391 is a 2-channel analog current output module specifically designed for the Series 90-30 Programmable Logic Controller system. This module converts digital data from the PLC CPU into high-resolution 4-20 mA analog signals, providing precise control over field devices such as variable speed drives, control valves, and industrial strip chart recorders. With its compact 1-slot design and robust electrical isolation, the IC693ALG391 is an essential component for high-accuracy closed-loop control applications.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | IC693ALG391 (Series 90-30) |
| Output Channels | 2 Current Outputs |
| Current Range | 4 to 20 mA |
| Resolution | 4 microamps (12-bit) |
| Isolation Voltage | 1500 VAC (Field to Logic) |
| Update Rate | 5 ms (for all channels) |
| Module Weight | 0.5 kg (1.1 lbs) |
| Power Requirement | 24 VDC Typical (20-30 VDC Range) |
Core Technical Advantages
Precise Signal Linearity
The IC693ALG391 is factory-calibrated to maintain a consistent 4µA per count, ensuring excellent linearity throughout the entire 4-20 mA spectrum. This precision allows for smooth ramping of motor speeds and fine-tuned valve positioning, reducing process variability and mechanical wear on field equipment.
High-Speed Response
With an update rate of just 5 ms for both output channels, this module is built for high-performance motion and process control. This fast conversion rate ensures that changes in the PLC control algorithm are reflected in the field almost instantly, supporting highly responsive system feedback loops.
Enhanced Industrial Safety
To protect the central Series 90-30 CPU and other I/O modules, the IC693ALG391 provides a 1500 VAC isolation barrier. This feature prevents electrical noise, ground loops, and accidental high-voltage transients on the field side from migrating back into the sensitive logic-side backplane.
Installation & Maintenance
- External Power: The module requires an external user supply voltage between 20 and 30 VDC. A stable 24 VDC supply is recommended for maximum accuracy and performance.
- Compact 1-Slot Design: Designed to fit any standard Series 90-30 I/O slot, its space-saving 1-slot width allows for a high concentration of control signals within a small cabinet footprint.
- Thermal Resilience: Built to operate reliably in harsh environments, the module supports a temperature range of -20°C to 60°C, ensuring consistent output signals regardless of ambient conditions.
Engineering Advantages
The IC693ALG391 is a robust solution for engineers who require dependable 4-20 mA current loops. Despite its high performance, it maintains low power consumption, reducing the thermal load within the PLC enclosure. Weighing just 0.5 kg, its lightweight yet durable construction makes it easy to integrate into both stationary and mobile industrial platforms, providing the long-term reliability expected of GE Fanuc industrial hardware.
Technical FAQs
Q1: Does this module support voltage output?
A1: No, the IC693ALG391 is specifically designed for current output (4-20 mA). For voltage applications, a different Series 90-30 analog module would be required.
Q2: What happens if the external 24V power supply fails?
A2: The module requires external power to drive the current loops. If external power is lost, the output channels will drop to 0 mA and the module will likely trigger a diagnostic fault in the PLC software.
Q3: Can the channels be configured for 0-20 mA output?
A3: The IC693ALG391 is primarily optimized for 4-20 mA. While data scaling can be performed in the PLC logic, the hardware calibration is tuned for the 4-20 mA standard for maximum resolution.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
