Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693ALG222
GE IC693ALG222 Series 90-30 16-Point Analog Voltage Unit
Manufacturer: General Electric
Product No.: IC693ALG222
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC693ALG222 is a high-density analog voltage input module designed to expand the capabilities of the Series 90-30 Programmable Logic Controller. This module provides up to 16 single-ended or 8 differential channels, allowing for the precise measurement of various voltage-based industrial signals. Whether monitoring bipolar inputs ranging from -10V to +10V or unipolar signals from 0V to +10V, the IC693ALG222 delivers the accuracy and electrical isolation required for sensitive process control environments.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | IC693ALG222 (Series 90-30) |
| Input Voltage Ranges | -10V to +10V (Bipolar), 0V to +10V (Unipolar) |
| Resolution | 2.5 mV (Unipolar), 5 mV (Bipolar) |
| Isolation Voltage | 1500 Volts RMS |
| Update Rate | 13 ms for all channels |
| Linearity | Less than 1 LSB |
| Module Weight | Approximately 0.35 kg (0.77 lbs) |
Core Technical Advantages
High-Density Input Capacity
The IC693ALG222 is optimized for space efficiency, offering 16 single-ended input channels in a single PLC slot. This high density allows engineers to monitor a large number of sensors, such as potentiometers or voltage-output pressure transducers, without requiring excessive rack space or additional expansion bases.
Superior Electrical Isolation
Safety and signal integrity are prioritized with 1500V RMS isolation between the field side and the PLC backplane. This robust barrier protects the Series 90-30 CPU from common-mode voltage spikes and electrical noise, ensuring that high-voltage transients in the field do not disrupt the control logic.
Precise Conversion and Linearity
With a linearity rating of less than 1 LSB and resolutions as fine as 2.5 mV, the IC693ALG222 provides highly faithful representations of analog field conditions. The internal hardware-based filtering (41 Hz or 82 Hz) ensures that readings remain stable, effectively rejecting high-frequency noise common in industrial power systems.
Installation & Maintenance
- Wiring Flexibility: The module can be configured for single-ended wiring (16 channels) or differential wiring (8 channels) for improved noise rejection on long cable runs.
- Backplane Power: The module draws power directly from the PLC backplane. Ensure the power supply module has sufficient capacity for this 0.35 kg unit alongside other I/O.
- Maintenance: Status LEDs on the front panel provide instant diagnostics, indicating the health of the module and the status of the field-side power.
Engineering Advantages
The IC693ALG222 is built for industrial durability, maintaining its performance across a wide range of operating conditions. Despite its comprehensive feature set, the module remains lightweight at approximately 0.35 kg, making it easy to handle during installation. Its software-configurable nature means that range selection and scaling can be performed through the programming environment, eliminating the need for manual hardware adjustments.
Technical FAQs
Q1: Can I use both unipolar and bipolar signals on the same module?
A1: The range is typically set for the whole module or in groups depending on the software configuration. Consult the GE Fanuc Series 90-30 manual for specific per-channel range flexibility.
Q2: What is the benefit of the 1500V RMS isolation?
A2: It provides a critical safety layer that prevents high-voltage "noise" or faults from the field wiring from reaching the sensitive digital circuitry of the PLC backplane and CPU.
Q3: Does this module require external 24VDC power?
A3: Yes, like most analog modules in the Series 90-30 line, external user power is required to drive the analog-to-digital conversion circuitry and maintain signal accuracy.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Joint Control Optimization Boost Manufacturing OEE by 20%?
Traditional disconnected PLC and DCS systems cause 10–18% daily idle time between production stages. This article pre...
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...