Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC694MDL240
GE Fanuc IC694MDL240 PLC Input Module
Manufacturer: General Electric
Product No.: IC694MDL240
Product Type: Discrete Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 280g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC694MDL240 Discrete Input Module
The GE Fanuc IC694MDL240 is a 16-point discrete input module for RX3i PacSystem. It operates at 120 Volts AC nominal with reliable 30 ms on and 45 ms off response times.
Core Specifications
- Brand: GE Fanuc
- Model: IC694MDL240
- Series: RX3i PacSystem
- Channels: 16 discrete inputs
- Voltage Range: 0-132V AC (120V AC nominal)
- Current Draw: 12 mA per channel, 90 mA total from 5V DC bus
- On-State Voltage: 74-132V AC
- Off-State Voltage: 0-20V AC
- Response Time: 30 ms on, 45 ms off
- Isolation: 250V AC optical, 1500V AC for 60 seconds
- LED Indicators: 16 channel status LEDs
Enhanced Performance Details
- MTBF: 400,000 hours
- Operating Temperature: -20°C to +60°C
- Storage Temperature: -40°C to +85°C
- Dimensions: 127 × 50 × 117 mm (H × W × D)
- Weight: 0.28 kg
- Surge Immunity: 1 kV per IEC 61000-4-5
- Shelf Life: 1 year from manufacture
Key Features
- High density: 16 inputs in a compact form factor
- Wide temperature range: Operates from -20°C to +60°C
- Excellent reliability: 400,000 hours MTBF
- Surge protection: 1 kV immunity per IEC standards
- Visual status: Individual LEDs for all 16 channels
Installation
- Compatibility: Works with all GE RX3i backplanes
- Power requirement: 5V DC from backplane bus
- Mounting: Directly plugs into RX3i rack
Package Includes
- 1 x IC694MDL240 discrete input module
Shipping
- Carriers: FedEx, UPS, DHL
FAQ
- How many input points does the IC694MDL240 have?
The IC694MDL240 provides 16 discrete input points with individual LED indicators.
- What voltage range activates an input?
Inputs turn on between 74 and 132 Volts AC. They remain off between 0 and 20 Volts AC.
- What is the response time for this module?
On response is 30 milliseconds. Off response is 45 milliseconds.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...