Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693NIU004
GE Fanuc IC693NIU004 Ethernet Network Interface Unit
Manufacturer: General Electric
Product No.: IC693NIU004
Product Type: Ethernet Network Interface Unit
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC693NIU004 is an Ethernet Network Interface Unit (NIU) designed for the Series 90-30 PLC platform. This module allows a standard Series 90-30 I/O baseplate to function as a high-capacity remote I/O drop over a standard Ethernet network. Instead of requiring a dedicated local CPU, the IC693NIU004 manages the local I/O rack communication and streams data directly to a centralized master controller. This architecture simplifies distributed control configurations across large plant floors, water treatment facilities, and material handling systems.
Technical Configuration
Core Technical Advantages
The IC693NIU004 features advanced processing capability to handle high-density data exchanges seamlessly. It provides built-in memory mapping for massive I/O counts, avoiding data bottlenecks during real-time plant updates. Operating as an Ethernet node, it plugs directly into the CPU slot of a Series 90-30 baseplate, utilizing standard TCP/IP communication protocols to bridge local digital and analog signals with the master supervisory control network over standard network infrastructure.
Technical Specifications
| Model Designation | IC693NIU004 |
| Product Series | GE Fanuc Series 90-30 PLC |
| Module Type | Ethernet Network Interface Unit (NIU) |
| Discrete Output Points (%Q) | 2048 points |
| Analog Input Channels (%AI) | 1268 channels |
| Analog Output Channels (%AQ) | 512 channels |
| Internal Logic Coils (%M) | 4096 points (fixed, system reserved) |
| Communication Interface | Ethernet RJ45 / TCP/IP Port |
| Net Weight | 0.50 kg |
Installation Guide
Mechanical Mounting and Slot Requirements
Ensure the rack power supply is turned completely off before starting installation. The IC693NIU004 must be installed in the dedicated CPU slot (Slot 1) of a standard Series 90-30 embedding baseplate. Hook the top latch of the module onto the chassis rail, swing downward until the backplane pins seat into the connector array, and secure the lower screw mount.
Ethernet Network Cabling
Connect a high-quality category 5e (Cat5e) or better shielded twisted-pair (STP) Ethernet cable into the RJ45 network port on the faceplate. Route the communication lines well away from high-power 3-phase motor conduits or variable frequency drives to prevent electromagnetic noise from degrading network packet health.
Hardware Address Assignment
Assign a unique IP address, subnet mask, and gateway configuration using the GE Fanuc machine configuration software utility. Download these settings via the local serial port or an initial default Ethernet broadcast loop before putting the slave node online.
Engineering Advantages
High Distributed Processing Capability
Supporting 2048 discrete outputs and 1268 analog inputs, the IC693NIU004 allows engineers to build massive local remote stations. This allows a single distributed drop to run complex automation cells featuring numerous pneumatic manifolds, instrumentation loops, and drive commands simultaneously.
Reduced Panel Cost and Footprint
By swapping out expensive field CPUs for a compact Network Interface Unit, users minimize engineering software licensing costs and drop panel space requirements. Data fields sync directly across standard Ethernet infrastructure, replacing thousands of expensive parallel field wiring runs with a single network connection.
Technical FAQs
Q1: Does the IC693NIU004 module support standalone user ladder logic execution?
A1: No. The NIU does not execute local user application programs. It acts exclusively as a smart network gateway that scans local I/O modules and mirrors data back to a master PLC over the Ethernet network.
Q2: Why are there %M internal coils reserved if the module doesn't run a user program?
A2: The 4096 internal %M coils are dedicated strictly to system utilities, network status flags, communications heartbeat monitoring, and internal fault diagnostics accessible by the master controller.
Q3: Can I place this module in a standard expansion slot instead of Slot 1?
A3: No. The IC693NIU004 controls the baseplate backplane scan loop. Because of this, it must be installed in the primary CPU slot of the baseplate to function correctly.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Is the Real Hourly Cost of Automation Downtime?
Industrial automation downtime creates severe financial losses, with PLC and DCS hardware failures causing 62% of unp...
-
Does Bently Nevada & PLC Integration Cut Refinery Downtime?
This article details a field-validated Bently Nevada 3500 and Allen-Bradley ControlLogix integration for oil and gas ...
-
Is Your Plant Ready for ABB-GE Fanuc Hybrid Control?
This article examines a hybrid ABB DCS and GE Fanuc PLC architecture for aging metallurgical lines, delivering 99.8% ...
-
Can Bently Nevada Integrate with Emerson DCS?
This article explores how Bently Nevada 3500 TSI and Emerson DeltaV DCS integration delivers measurable predictive ma...
-
Why 38% of Refinery Shutdowns Start with Aging PLCs?
This article examines how genuine GE Fanuc PLC spare parts and Bently Nevada TSI monitoring cards enable Industry 4.0...
-
Can Integrated DCS-PLC Solve Food Production Inconsistency?
This article examines how integrating Emerson DeltaV DCS with Allen‑Bradley PLC resolves food manufacturing control p...
