Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693ALG223
GE Fanuc IC693ALG223 Series 90-30 16-Channel Analog Input Module
Manufacturer: General Electric
Product No.: IC693ALG223
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The GE Fanuc IC693ALG223 is a high-density, 16-channel analog current input module specifically engineered for the Series 90-30 Programmable Logic Controller. This advanced module allows for the simultaneous monitoring of up to 16 independent current loops, supporting standard ranges such as 4-20 mA and 0-20 mA, as well as an "Enhanced" 4-20 mA mode for improved error detection. With its robust 1500V field-to-logic isolation and integrated low-pass filtering, the IC693ALG223 is a premier choice for large-scale industrial data acquisition where precision and signal integrity are vital.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | IC693ALG223 (Series 90-30) |
| Total Channels | 16 (Selectable per channel) |
| Input Ranges | 4-20 mA, 0-20 mA, 4-20 mA Enhanced |
| Resolution | 4 µA (4-20 mA) / 5 µA (0-20 mA) |
| Isolation Voltage | 1500 Volts (Field to Logic) |
| Update Rate | 13 ms for all 16 channels |
| Module Weight | 0.5 kg (1.1 lbs) |
| Accuracy | ± 0.25% of Full Scale @ 25°C |
Core Technical Advantages
Maximum Channel Density
The IC693ALG223 maximizes the efficiency of your PLC rack by offering 16 input channels in a single slot. This high density significantly reduces the physical hardware footprint and the number of modules required for large systems, making it an economically and technically superior choice for complex automation projects.
Superior Signal Integrity and Filtering
To ensure clean data in noisy industrial environments, the module features a 19 Hz low-pass filter response and a cross-channel rejection rate of over 80 dB. These features work in tandem with the 250-ohm input impedance to eliminate electromagnetic interference (EMI) and crosstalk, providing stable and repeatable readings from every sensor.
Comprehensive Electrical Protection
With a 1500V isolation barrier between the field-side wiring and the PLC logic side, the IC693ALG223 protects your central processor from ground loops and high-voltage transients. This protective design ensures that a fault in one field device does not propagate through the system and cause a catastrophic PLC failure.
Installation & Maintenance
- Power Requirements: The module draws 120 mA from the +5V backplane bus and requires an additional 65 mA from a user-supplied 24 VDC source to power the analog-to-digital conversion circuitry.
- Enhanced Mode: Utilize the 4-20 mA Enhanced range to enable under-range detection (signals below 4mA), allowing the PLC to identify and alarm on broken field wires.
- Mechanical Handling: Weighing 0.5 kg, the module is built with industrial-grade materials to withstand vibration and thermal cycling common in factory floor control cabinets.
Engineering Advantages
The IC693ALG223 provides high-resolution data conversion (as fine as 4 µA) and maintains consistent absolute accuracy (±0.5% over the full temperature range). Weighing 0.5 kg, this module is robustly designed for long-term installation. It allows engineers to customize the input type for every individual channel via the PLC software, providing a highly adaptable solution that can be reconfigured as field requirements evolve without changing physical hardware.
Technical FAQs
Q1: What is the difference between standard and "Enhanced" 4-20 mA ranges?
A1: Enhanced mode allows the module to report negative values if the signal drops slightly below 4mA (down to 0mA), which is useful for diagnosing sensor calibration issues or detecting wire breaks.
Q2: Does this module require external 24VDC power?
A2: Yes. The module requires 65 mA from an external 24 VDC user supply to correctly bias the analog inputs and drive the 1500V isolation circuitry.
Q3: Is it possible to mix 0-20mA and 4-20mA signals on the same module?
A3: Yes. Each of the 16 channels can be independently configured for its own specific range through the PLC programming software.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Joint Control Optimization Boost Manufacturing OEE by 20%?
Traditional disconnected PLC and DCS systems cause 10–18% daily idle time between production stages. This article pre...
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
