Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-IF8
Analog Input Module 1756-IF8 Allen-Bradley 8-Channel
Manufacturer: Allen-Bradley
Product No.: 1756-IF8
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 327g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley ControlLogix 1756-IF8 8-Channel Analog Input Module
The 1756-IF8 is an 8-channel analog input module from the Allen-Bradley ControlLogix series. Rockwell Automation designed this module for industrial applications requiring 0-10V voltage or 4-20mA current signal acquisition. It features 250V channel isolation and operates from 0°C to 60°C.
Key Specifications
- Part Number: 1756-IF8
- Brand: Allen-Bradley / Rockwell Automation
- Series: ControlLogix
- Module Type: Analog Input
- Number of Inputs: 8 channels
- Signal Range: 0-10V / 4-20mA
- Channel Isolation: 250V
- Weight: 0.327 kg
Electrical Specifications
- Backplane Current (5V): 150 mA
- Backplane Current (24V): 40 mA
- Power Dissipation (Voltage Mode): 1.73 W
- Power Dissipation (Current Mode): 2.33 W
Environmental Specifications
- Operating Temperature: 0°C to 60°C
- Storage Temperature: -40°C to 85°C
- Relative Humidity: Up to 95% non-condensing
- Vibration Resistance: 2 m/s²
- Frequency Range: Up to 500 Hz
Key Features
- 8 differential analog inputs for flexible configuration
- 250V channel-to-channel isolation prevents ground loops
- Supports both voltage (0-10V) and current (4-20mA) signals
- Compatible with all ControlLogix chassis and processors
- Requires 1756-TBCH or 1756-TBS6H terminal blocks
Package Includes
- 1x Allen-Bradley 1756-IF8 analog input module
- 1x installation documentation
Technical Documentation
📥 Download Product Datasheet PDF
FAQ
1. How many channels does the 1756-IF8 have?
The 1756-IF8 features 8 differential analog input channels for voltage or current signals.
2. What signal ranges does this module support?
It supports 0-10V voltage and 4-20mA current input signals.
3. What is the isolation rating between channels?
The module provides 250V channel-to-channel isolation to prevent ground loops and interference.
Additional Specifications
- Gray
- Black
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Why Is 99.8% Reliability Critical for Your PLC and DCS Systems?
This article explains why rigorously vetted cross-border control parts stabilize industrial automation operations. It...
-
Can Joint Control Optimization Boost Manufacturing OEE by 20%?
Traditional disconnected PLC and DCS systems cause 10–18% daily idle time between production stages. This article pre...
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...