Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-IT6I
Allen-Bradley 1756-IT6I ControlLogix 6-Channel Isolated Thermocouple Module
Manufacturer: Allen-Bradley
Product No.: 1756-IT6I
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1756-IT6I is a premium, high-resolution 6-channel isolated thermocouple input module belonging to the elite ControlLogix automation family. Engineered for precise temperature tracking in harsh processing environments, this module features six individually isolated thermocouple channels alongside an independent Cold-Junction Compensation (CJC) input. Weighing approximately 0.32 kg (0.71 lbs), this compact chassis-mounted module delivers exceptional 16-bit analog-to-digital conversion directly within the ControlLogix backplane system, safeguarding your thermal loops against erratic ground potentials and high-frequency electromagnetic noise without adding substantial structural strain.
Core Technical Advantages
- Individually Isolated Channels: Features complete channel-to-channel and channel-to-backplane electrical isolation, effectively suppressing common-mode line interference and ground loops to maintain flawless measurement accuracy.
- Dual-Mode High-Resolution Sensing: Delivers a sharp 16-bit diagnostic architecture, providing ultra-fine typical resolution down to 0.7 microvolts per bit when operating within the high-resolution millivolt range.
- Versatile Data Representation: Supports multiple processing profiles including left-justified two's complement integer formatting and standard IEEE 32-bit floating-point arrays for seamless controller scaling.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix System) |
| Model Part Number | 1756-IT6I (Series A/B Compatible) |
| Gross Weight | 0.32 kg (0.71 lbs) |
| Analog Inputs Count | 6 isolated thermocouple inputs and 1 dedicated CJC sensor path |
| Standard Signal Range | minus 12 to plus 78 mV (typical resolution of 1.4 microvolts/bit) |
| High-Resolution Range | minus 12 to plus 30 mV (typical resolution of 0.7 microvolts/bit) |
| Backplane Bus Current | 250 mA at 5 VDC / 125 mA at 24 VDC |
| Maximum Power Dissipation | 4.3 Watts maximum under peak operational thermal load |
| Minimum Module Scan Time | 10 ms (integer mV), 25 ms (float mV), 50 ms (float temperature) |
| Removable Terminal Blocks | Compatible with 1756-TBNH and 1756-TBSH mechanical blocks |
Installation & Engineering Guide
- Chassis Slot Integration: Shut down the primary control rack power supply before installation. Slide the 0.32 kg hardware framework smoothly into any open slot of the ControlLogix chassis, ensuring the top and bottom retention guides are firmly locked onto the structural framing rails.
- CJC Terminal Assembly: Wire the external field sensor loops through a compatible 1756-TBNH or 1756-TBSH removable terminal block. Ensure that the dedicated Cold-Junction Compensation (CJC) thermistor is correctly seated and wired to optimize absolute thermal tracking.
- Scan Time Optimization: Select the matching data format profile in your Logix Designer programming environment. If executing fast-acting loop dynamics, select the integer millivolt mode to drop the native module processing latency down to a 10 ms cycle.
Technical FAQs
Q1: What structural advantage does channel-to-channel isolation provide on the 1756-IT6I?
A1: Channel-to-channel isolation guarantees that each individual thermocouple sensor operates on an independent electrical plane. If one field thermocouple accidentally shorts to a high-voltage metal casing, the resulting surge is confined to that channel, fully protecting the other five sensors and the core PLC processor backplane from cascading failures.
Q2: Why does this module require a separate CJC input path?
A2: A Cold-Junction Compensation input is necessary because terminating thermocouple wires into copper terminal blocks creates secondary thermoelectric junctions. The CJC sensor tracks ambient block temperatures in real time, allowing the internal software to mathematically cancel out terminal errors and maintain accurate sensor telemetry.
Q3: Does the lightweight profile of this module impact its structural stability under high-vibration conditions?
A3: No. At only 0.32 kg, its specialized lightweight engineering optimizes the module for dense multi-slot configurations while easily satisfying standard ControlLogix industrial specifications for shock, thermal endurance, and heavy industrial vibration mapping.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Stop 68% of DCS Faults with Proven Transmitter Matching Rules?
This article presents field-verified solutions for optimizing communication between Rosemount transmitters and Emerso...
-
What Does Poor PLC Backup Cost Your Paper Plant?
This technical article presents quantified backup and recovery standards for GE Fanuc RX7i PLCs in high-capacity pape...
-
Why Do 42% of Offshore DCS Downtime Events Trace to Power Modules?
This technical analysis examines the root causes of Allen‑Bradley power module failures in offshore control cabi...
-
Can Layered PLC Fix Chemical Batch Failures?
This technical article presents field-validated ABB AC800M configuration strategies for high-stability fine chemical ...
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
