Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:3BSE018124R1
ABB CI853 3BSE018124R1 | RS-232 Modbus Module
Manufacturer: ABB
Product No.: 3BSE018124R1
Product Type: Interface Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The ABB CI853 (3BSE018124R1) is a high-performance dual-channel RS-232 communication interface specifically engineered for the AC 800M controller family. This module enables reliable serial integration between your control system and external peripherals such as PLCs, weight scales, and operator panels. By supporting Modbus RTU and COMLI protocols, the CI853 provides a versatile gateway for multi-vendor data synchronization in demanding industrial environments.
Technical Specifications
| Feature | Details |
|---|---|
| Brand / Series | ABB / AC 800M |
| Model ID | CI853 (3BSE018124R1) |
| Channels | 2 x RS-232C Ports |
| Protocols | Modbus RTU, COMLI (Master/Slave) |
| Baud Rate | 75 to 19,200 bps |
| Connector Type | RJ-45 (8-pin) |
| Protection Class | IP20 / G3 Compliant |
Engineering Advantages
Corrosion & Industrial Resilience
The module features G3 compliant conformal coating, ensuring long-term reliability in corrosive atmospheres (ISA 71.04). This makes it ideal for chemical plants and offshore applications.
Hot Swap Capability
The CI853 hardware supports Hot Swap technology. Maintenance teams can replace the interface module while the controller remains energized, significantly reducing system downtime.
High Integrity Compatibility
This interface operates seamlessly with High Integrity (HI) controllers, providing the necessary serial links for safety-related monitoring and auxiliary control tasks.
Installation & Maintenance Guide
- Physical Mounting: Secure the module onto the TP858 baseplate and confirm the CEX-Bus pins are correctly aligned.
- Cable Integrity: Use high-quality shielded RJ-45 cables. Ensure RS-232 cable runs do not exceed 15 meters to prevent data corruption.
- Configuration: Define the port parameters (Baud Rate, Parity) within the ABB Control Builder M environment to match your field device.
Technical FAQs
Q1: Does the CI853 support redundant communication?
A1: No, the CI853 does not support line or module redundancy. For critical paths, we recommend utilizing dual modules on the CEX bus.
Q2: Can I use this for Modbus TCP/IP?
A2: No, the CI853 is strictly for serial RS-232 (Modbus RTU). For Modbus TCP/IP, you would typically require a CI867 module.
Q3: What is the maximum number of CI853 units per controller?
A3: You can connect up to 12 modules to the CEX-Bus of a single AC 800M controller, depending on the power supply capacity.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
