Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:330104-00-07-10-02-05
330104-00-07-10-02-05 Bently Nevada 3300 XL 8mm Proximity Probe
Manufacturer: Bently Nevada
Product No.: 330104-00-07-10-02-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Bently Nevada 330104-00-07-10-02-05 is a high-precision 3300 XL 8mm Proximity Probe featuring a metric M10 x 1 thread and integrated stainless steel armor. This sensor is a core component of the 3300 XL series, designed to measure radial vibration and axial position on fluid-film bearing machines. With its rugged construction and ClickLoc miniature coaxial connector, it provides superior signal stability and reliability in demanding industrial environments such as power plants and refineries.
Technical Configuration
- Manufacturer: Bently Nevada (Baker Hughes)
- Part Number: 330104-00-07-10-02-05
- Unthreaded Length: 00 mm
- Overall Case Length: 70 mm
- Total Length: 1.0 Meter (3.3 feet)
- Connector Type: Miniature coaxial ClickLoc (Standard Cable)
- Armor Option: Integrated Stainless Steel Armor
- Agency Approvals: CSA, ATEX, and IECEx Multi-certified (-05)
Technical Specifications
| Linear Range | 2 mm (80 mils) | DC Resistance | 7.59 Ω ± 0.50 Ω |
| Operating Temp | -52°C to +177°C | Unit Weight | 323 g/m (11.4 oz/m) |
| Tip Material | Polyphenylene sulfide (PPS) | Case Material | AISI 303/304 Stainless Steel |
Mechanical & Environmental Protection
1. Metric Threading: The 330104 series utilizes a standard M10 x 1 metric thread. This specific model features a 70mm case length with no unthreaded portion, allowing for deep thread engagement up to 15mm within the machine case or housing. The robust build reflects a typical weight of 323 grams per meter, ensuring mechanical stability under vibration.
2. Advanced Materials: The probe tip is manufactured from Polyphenylene sulfide (PPS), a high-performance thermoplastic that resists chemical attack and moisture absorption. The probe case is constructed from 303 or 304 stainless steel, providing excellent corrosion resistance and mechanical strength.
3. ClickLoc Connector: The ClickLoc miniature coaxial connector is gold-plated for maximum conductivity and features a locking mechanism that prevents accidental disconnection due to high-frequency machine vibration.
Installation Guidelines
Recommended Gap Setting: For radial vibration monitoring, a nominal gap of -9 Vdc (approximately 1.27 mm or 50 mils) is recommended. This places the sensor in the center of its 2mm linear range for optimal measurement accuracy.
Hazardous Area Wiring: When used in intrinsically safe applications (Class I, Zone 0), the probe must be installed with approved zener barriers or galvanic isolators per Bently Nevada drawing 141092. For Division 2 / Zone 2 areas, non-incendive wiring practices must be followed.
Pressure Seal Caution: While the probe tip is rated for high temperatures, exposing the probe to temperatures below -34°C (-30°F) may compromise the Viton O-ring pressure seal. If your application involves significant differential pressure, contact technical support for verification.
Technical FAQs
Q1: What is the maximum distance between the probe and the Proximitor Sensor?
A1: The total length of the probe and extension cable must match the Proximitor Sensor's calibration (typically 5 or 9 meters). This specific probe is a 1.0-meter version, requiring a matching extension cable.
Q2: Is this probe compatible with standard 3300 XL Proximitor Sensors?
A2: Yes, it is fully compatible with the 3300 XL series, providing a scale factor of 7.87 V/mm (200 mV/mil).
Q3: How does the stainless steel armor protect the probe?
A3: The armor provides mechanical protection against crushing or abrasion for the internal coaxial cable, making it ideal for routing through harsh industrial areas or internal machine pathways.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Is Your SME Process Factory Overpaying for Industrial Automation?
This article provides a data-driven guide for SME process factories to deploy right-sized DCS solutions without overs...
-
Why Did a $420,000 Shutdown Happen Despite CPU Redundancy?
This article presents 15 years of field-tested evidence showing how hidden single points of failure cause unplanned s...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...
-
Why Multi-Protocol Chaos Hinders Automation Upgrades?
This article explains how cross-protocol data interconnection resolves heterogeneous device barriers in smart factory...
-
Can Bently Nevada Spectrum Analysis Predict Rotating Equipment Failures?
Traditional PLC and DCS systems fail to detect gradual vibration anomalies causing 78% of rotating equipment failures...