  • Product No.: PR9268/204-000

  • Product Type: Eddy Current Sensor

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 400g

  • Shipping port: Xiamen

  • Warranty: 12 months

30 dagen retourbeleid · 12 maanden garantie
  • Snelle levering
  • 24/7 Ondersteuning
  • Kwaliteitsborging

Beschrijving

Emerson PR9268/204-000 Eddy Current Sensor

The Emerson PR9268/204-000 is a precision eddy current sensor designed for continuous vibration and displacement monitoring. It delivers reliable performance for protecting critical rotating equipment.

Technical Specifications

  • Brand & Model: Emerson PR9268/204-000
  • Measuring Range: 2.0 mm
  • Linear Range: 1.5 mm
  • Sensitivity: 8 Volts per millimeter (V/mm)
  • Output Signal: -2 to -18 Volts DC
  • Supply Voltage: -24 Volts DC
  • Frequency Response: 0 to 3000 Hz
  • Operating Temperature: -20°C to +120°C
  • Cable Length: 5 meters (standard)
  • Weight (Approximate): 0.4 kg (0.88 lbs) for sensor with cable

Package Contents & Support

  • Package Includes:
    • One PR9268/204-000 sensor
    • One 5-meter cable
    • Mounting instructions
  • Shipping: Worldwide delivery via FedEx, UPS, or DHL. Orders placed before 3 PM typically ship same day with tracking provided.
  • Warranty & Support: Backed by a 12-month warranty and 24/7 technical support.

FAQ

  • Q: What does the PR9268/204-000 sensor measure?
    A: It measures the distance (gap) between the sensor tip and a conductive metal target (usually a shaft), converting this into a voltage proportional to vibration or positional change.
  • Q: What is the difference between measuring range and linear range?
    A> The measuring range (2.0mm) is the total distance the sensor can detect. The linear range (1.5mm) is the portion of that range where the output signal is guaranteed to have a straight-line relationship with distance, ensuring highest accuracy.
  • Q: Why is a negative supply voltage (-24V DC) used?
    A: This is a common standard for many eddy current sensor systems. The negative output signal increases in magnitude as the gap decreases.

Technical Documentation

Download Detailed Specifications (PDF)

For pricing and technical support for the PR9268/204-000, contact us at sale@etowonauto.com.

🏷️ Tags: Eddy Current Sensor
  • Zwart
  • Zilver

Scalar (V/f)

Vector

Op netstroom

  • Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
  • Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
  • Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
  • Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
  • Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.

Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.

Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.

Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

Alle details bekijken

ZORG VOOR BETROUWBARE MACHINEPRESTATIES

Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.