Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:IC697BEM741
IC697BEM741 GE Fanuc Series 90-70 FIP Bus Controller
Manufacturer: General Electric
Product No.: IC697BEM741
Product Type: Controller Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 1810g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The IC697BEM741 is a high-reliability FIP / WorldFIP (EN50170) Fieldbus Controller module designed for the GE Fanuc Series 90-70 programmable logic controller (PLC) platform. Operating as a single-slot Bus Expansion Module, this interface card establishes a deterministic network gateway capable of managing up to 128 connected field devices at a data communication speed of 1.0 Megabits per second (Mbps). Weighing approximately 4.0 pounds (1.81 kg), it provides heavy-duty central processing units with decentralized remote input/output capability, maximizing network reach across large industrial automation plants.
Core Technical Advantages
-
Detailed Suffix Logic Breakdown:
- IC697: Confirms native form-factor integration with the GE Fanuc Series 90-70 VME backplane ecosystem.
- BEM: Designates a dedicated Bus Expansion Module engineered for specialized network communication.
- 741: Specifies the operational hardware variant for the standard FIP/WorldFIP Fieldbus architecture.
- Dual-Channel Physical Layers: Features two discrete 9-pin FIP Bus connection ports (Channel 1 and Channel 2), providing robust physical line routing options for distributed device drops.
- Optimized Power Footprint: Draws a steady 1.3 Amps from the local backplane at a tight 5.0 VDC ($\pm$0.1 VDC) supply tolerance, keeping maximum power consumption below 6.5 Watts.
- High Device Concentration: Addresses and scans up to 128 individual field devices, including Series 90-30 PLCs, remote I/O scanner racks, and computer terminals over a network loop spanning up to 1000 meters.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Number | IC697BEM741 |
| Communication Protocol | FIP / WorldFIP Fieldbus standard (EN50170 compliance) |
| Bus Baud Rate | 1.0 Megabits per second (Mbps) continuous transmission |
| Device Addressing Limit | Up to 128 remote fieldbus nodes or distributed I/O targets |
| Network Scan Interval | Deterministic full sweep in 5 ms to 50 ms (node-count dependent) |
| Physical Connections | 2x 9-pin FIP ports (Ch1/Ch2) | 1x 15-pin RS-232 serial interface |
| Chassis Rack Compatibility | Installs in single slots of IC697CHS782 and IC697CHS783 VME racks |
| Operational Climate | 0°C to 60°C (32°F to 140°F); 5% to 95% non-condensing relative humidity |
| Hardware MTBF Rating | Validated in excess of 250,000 continuous operation hours |
Installation & Maintenance Guide
Chassis Mounting & Slot Seating
Turn off all input power to the automation rack before beginning. Slide the IC697BEM741 card directly into an open physical slot of an IC697CHS782 or IC697CHS783 VME style chassis. Seat the rear card-edge contacts fully into the backplane connectors and firmly hand-tighten the integrated faceplate screws to provide solid grounding.
FIP Bus Line & Segment Routing
Connect network trunk segments to the twin 9-pin FIP bus ports. Ensure high-quality shielded twisted-pair cabling is utilized to maintain the 1.0 Mbps transmission speed over longer spans. Keep total unrepeated copper cable lengths below 1000 meters, accounting for signal attenuation factors and proper end-of-line termination resistors.
Hardware Reset & Maintenance
The faceplate features a rugged manual mechanical pushbutton that triggers an immediate local hardware reset. This allows system engineers to clear minor communication lockups or re-initialize the onboard network chips instantly at the panel door without requiring software overrides or resetting the master PLC controller.
Engineering Advantages
- Deterministic I/O Scanning: Refreshes and synchronizes data maps from all 128 remote stations systematically during every continuous bus cycle, preventing critical real-time variable skew.
- Local Configuration Retention: Features non-volatile configuration memory storage that securely holds complex network mapping variables and address settings through total facility power outages.
- At-a-Glance Diagnostics: Integrates a 6-LED physical display, featuring MODULE OK and RUN indicators at the top, supplemented by 4 channel-specific LEDs for real-time serial traffic and error tracing.
- Dedicated Firmware Uplink: Includes an independent 15-pin RS-232 serial interface port exclusively allocated for field-level firmware upgrades, insulating operational code from network data paths.
Technical FAQs
Q1: What software is required to configure the network maps on this module?
A1: The communication parameters and remote device maps are fully configured and managed using standard Logicmaster 90-70 (Windows variant) or CIMPLICITY Control 90 engineering software packages.
Q2: Can this controller operate on standard RS-485 serial networks?
A2: No. The IC697BEM741 is purpose-built to execute the specific FIP/WorldFIP fieldbus protocols (EN50170). It cannot interface directly with traditional Modbus RTU or generic RS-485 industrial lines without an inline protocol converter.
Q3: What causes the network scan interval to shift between 5 ms and 50 ms?
A3: The overall cycle time depends directly on the total number of live fieldbus nodes active on the network and the volume of cyclic data points requested. Fewer drops will drive the system toward the fast 5 ms benchmark, while a maxed-out 128-device bus triggers longer scan times.
Aanvullende specificaties
- Groen
- DC-gevoed
- Modulair
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Waarom is een failover van 50 ms cruciaal voor slimme fabrieken in Industrie 4.0?
Dit artikel onderzoekt het ABB DCS full-link redundantieontwerp voor farmaceutische productie onder GMP- en Industry ...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...