Meteen naar de content
Automatiseringsonderdelen, wereldwijde levering
Ga direct naar productinformatie
1 van 3

SKU:FC-TDOL-07120

Honeywell FC-TDOL-07120 Digital Output Module

Nog maar 2 stuks beschikbaar
  • Manufacturer: Honeywell

  • Product No.: FC-TDOL-07120

  • Product Type: Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1200g

  • Shipping port: Xiamen

  • Warranty: 12 months

30 dagen retourbeleid · 12 maanden garantie
  • Snelle levering
  • 24/7 Ondersteuning
  • Kwaliteitsborging

Beschrijving

Product Overview

The FC-TDOL-07120 (general type FS-TDOL-07120) is a 7-channel line-monitored Field Termination Assembly (FTA) module designed for the Honeywell Safety Manager system. This module serves as a heavy-duty power interface for critical field loads requiring 120Vac or 120Vdc digital outputs. Equipped with 7 fused relay contact outputs, it bridges low-voltage control logic with high-capacity field equipment, providing integrated loop diagnostics and high galvanic isolation for emergency shutdown and critical control loops.

Core Technical Advantages

  • Advanced Line Monitoring: Integrates dedicated surveillance circuits across all 7 output channels to detect open and short circuits in field wiring.
  • High-Capacity Switching: Features robust onboard relays supporting industrial field loads up to 240VA (AC) or 150W (DC) per channel.
  • Cross-Module Interconnection: Connects seamlessly with SDO-0824 output and SDI-1624 input modules via standard system cables to drive logic and process faults.
  • Visual Diagnostics: Includes dedicated status LEDs for each relay channel, allowing instantaneous visual verification of output states during maintenance.

Technical Specifications

Parameter Specification Details
Model Number FC-TDOL-07120 / FS-TDOL-07120
Channel Count 7 Digital Output Channels
Output Supply Voltage 120V AC or 120V DC (+/- 20%)
Max Output Current 2A per channel (at 120V AC)
Maximum Channel Load 240VA (Resistive/Inductive) or 150W
Channel Protection 2A individual channel fuses
Expected Relay Life 100,000 electrical operations / 30,000,000 mechanical operations
Mounting Options DIN EN rails: TS32 / TS35 x 7.5
Dimensions (L x W x H) 240 x 109 x 71 mm
Approvals CE, UL, CSA, TUV

Installation & Maintenance Guide

Module Wiring and Interconnection

Interface the module to the upstream control layers using dedicated system interconnection cables. Connect channels 1 through 7 of the SDO-0824 module to control the respective output relays, and wire the integrated line-monitoring outputs back to channels 1 through 15 of the SDI-1624 input module.

DIN Rail Mounting

Snap the rugged housing securely onto standard DIN EN rails (compatible with TS32 or TS35 × 7.5 profiles). Ensure sufficient clearance around the assembly inside the enclosure to facilitate heat dissipation from inductive loads and allow clear visibility of the relay state LEDs.

Fuse and Service Safeties

Each output channel is individually isolated by a 2A fuse. If a field short-circuit occurs, isolate the main 120V power source before extracted or replacing the blown fuse. Always execute test operations via the application logic to verify loop feedback integrity post-replacement.

Engineering Advantages

  • Universal Load Capability: Formulated to switch both inductive and resistive industrial field loads safely without requiring external snubber circuits.
  • High Operational Lifespan: Heavy-duty relay construction delivers up to 30 million mechanical cycles, lowering total cost of ownership and minimizing downtime.
  • Full Safety Compliance: Backed by CE, UL, CSA, and TUV certifications, ensuring seamless deployment within strict regulatory and SIL-rated environments.

Technical FAQs

Q1: How does the line-monitoring feature operate on this module?
A1: Line-monitoring circuits on each channel track field loop continuity. This diagnostic routing is activated by channel 8 of the SDO-0824 module and processed via channels 1 to 15 of the SDI-1624 input module using specialized application logic.

Q2: Can I mix 120V AC and 120V DC loads on the same module?
A2: While the contacts are rated for both 120V AC and 120V DC (+/- 20%), it is standard engineering practice to maintain consistent voltage types across a single physical board to prevent cross-contamination of power rails.

Q3: What is the maximum switched power rating for the contacts?
A3: The relay contacts support a maximum switched power threshold of 1250VA for alternating current loops and 60 Watts for direct current safety loops.

🏷️ Tags: Output Module
  • DC-gevoed
  • Compact
  • Modulair

Scalar (V/f)

Vector

Op netstroom

  • Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
  • Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
  • Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
  • Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
  • Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.

Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.

Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.

Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

Alle details bekijken

ZORG VOOR BETROUWBARE MACHINEPRESTATIES

Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.