GE IS200EDCFG1A EDCF Exciter DC Feedback Module EX2100
Manufacturer: General Electric
Product No.: IS200EDCFG1A
Product Type: Feedback Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The General Electric IS200EDCFG1A (functional acronym EDCF) is an Exciter DC Feedback Board designed for the GE EX2100 Series Excitation Control System. Mounted directly at the Silicon Controlled Rectifier (SCR) bridge, this module measures and conditions critical generator field voltage and field current feedback signals for real-time excitation control.
To ensure high noise immunity and complete electrical isolation in harsh high-voltage power generation environments, the IS200EDCFG1A converts analog voltage and current inputs into high-speed fiber-optic pulse streams transmitted directly to the EISB board in the control rack. Operating on an external 24 V DC power supply, the board weighs approximately 0.45 kg (0.99 lbs) and is rated for operation across temperatures ranging from -30°C to +65°C.
Core Technical Advantages
- Noise-Immune Fiber-Optic Transmission: Utilizes dual fiber-optic links (plastic for up to 10 m, hard-clad silica for up to 90 m) to transmit isolated feedback signals without electromagnetic interference.
- Selectable Field Voltage Scaling: Provides seven adjustable jumper settings to attenuate and scale SCR bridge voltages before feeding differential VCO circuitry.
- Precision Field Current Measurement: Monitors low-level DC shunt outputs (up to 500 mV) and amplifies them into a -5V to +5V range for high-accuracy current tracking.
- Onboard Voltage Regulation: Converts external 24 V DC power into isolated +15 VDC, -15 VDC, and +5 VDC rails, featuring a front-panel PSOK green LED indicator.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | General Electric (GE) |
| Catalog Part Number | IS200EDCFG1A |
| Functional Acronym | EDCF (Exciter DC Feedback Board) |
| System Compatibility | GE EX2100 Excitation Control System |
| Hardware Revision / Form | Hardware Form A (Not Backward Compatible) |
| External Power Supply | 24 V DC (via Connector J16) |
| Internal Voltage Rails | +15 VDC, -15 VDC, +5 VDC (regulated onboard) |
| Field Voltage Input | Stab-on terminal E1 (7 jumper-selectable scaling settings) |
| Field Current Input | Connector P1 (DC shunt low-level signal up to 500 mV max) |
| Fiber-Optic Distances | Plastic: up to 10 m; Hard-Clad Silica: up to 90 m |
| Net Board Weight | 0.45 kg (0.99 lbs) |
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
| Documentation Manuals | GEI-100464 / GEI-100464A, GEH-6632 |
Installation & Gap Calibration Guide
- Wiring Connections: Attach the 24 V DC supply to connector J16, the current shunt signal to P1, and the field voltage sensing line to stab-on connector E1.
- Fiber-Optic Cable Routing: Route two fiber-optic cables from the EDCF to the EISB board, ensuring a minimum bending radius of 1.5 inches (38 mm) to avoid signal degradation.
- Power Verification: Confirm that the green PSOK LED illuminates upon applying 24 V DC, verifying correct function of the internal ±15 VDC regulators.
Technical FAQs
Q1: What is the main function of the GE IS200EDCFG1A board?
A1: It senses field voltage/current at the SCR bridge and transmits optical data to the EISB board. (95 chars)
Q2: What cable types and distances are supported for fiber transmission?
A2: Plastic fiber supports distances up to 10 m, while hard-clad silica fiber reaches up to 90 m. (93 chars)
Q3: How is field current measured by the IS200EDCFG1A module?
A3: It measures a 500 mV max DC shunt voltage across connector P1, converting it into a VCO frequency. (96 chars)
Aanvullende specificaties
- Groen
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...